Judul ArtikelANALISIS PEMASANGAN SYNCHRONOUS CLOSING BREAKER TERHADAP ARUS DAN TEGANGAN TRANSIEN PADA CAPACITOR BANK SWITCHING
DI PT. HOLCIM INDONESIA TBK. CILACAP PLANT
Abstrak (Bhs. Indonesia)Proses capacitor bank switching mengakibatkan penurunan kualitas daya listrik berupa arus dan tegangan transien. Beberapa metode digunakan untuk mengurangi arus dan tegangan transien tersebut. Penelitian ini akan menganalisis tentang pengaruh pemasangan synchronous closing breaker sebagai metode untuk mengurangi arus dan tegangan transien akibat dari capacitor bank switcthing. Analisa dilakukan menggunakan simulasi software ATP-EMTP dengan objek penelitian pada sistem kelistrikan industri PT. Holcim Indonesia Tbk. Cilacap Plant. Dari hasil penelitian menunjukan bahwa kenaikan arus saat transien mencapai 7360,6 A untuk pengoperasian single bank switching dan 5263,5 A untuk pengoperasian secara back to back. Tegangan pada saat transien pada saat pengoperasian single bank switching mencapai 9207,7 V dan 9523,9 V saat pengoperasian secara back to back dari tegangan steady 4934,7 V dengan durasi yang sangat singkat. Dan penggunaan synchronous closing breaker pengaruhnya sangat signifikan dalam mereduksi arus dan tegangan transien dari hasil simulasi, arus transien mencapai 2413,9 A dan tegangan transien mencapai 5057,2 V.
Abtrak (Bhs. Inggris)Capacitor bank switching process resulting in decreaseed quality of electrical power in form current and voltage transients. Several methods are used to reduce the current and voltage transients. This study will analize the effect of the installation of synchronous closing breaker as a method to reduce the current and voltage transients due to capacitor bank switcthing. This research study analyzes the theory and use the help of ATP-EMTP simulation software with the object of research in industrial electrical systems PT. Holcim Indonesia Tbk. Cilacap Plant. From the results of the study showed that the increase in transient current flows reached 7360.6 A for the operation of the single bank switching and 5263.5 A for the operation of the back-to-back. Voltage transient during operation at a single bank switching reached 9207.7 V and 9523.9 V when operating in back to back from 4934.7 V steady voltage with a very short duration. And the use of synchronous closing breaker highly significant effect in reducing current and voltage transients from the simulation results, reaching 2413.9 A transient current and transient voltage reaches 5057.2 V.
Kata kuncicapacitor bank switching, transien, synchronous closing breaker, ATP-EMTP
Pembimbing 1Winasis, ST., M.Eng
Pembimbing 2Daru Tri Nugroho, ST., MT
Pembimbing 3
Tahun2013
Jumlah Halaman7
Tgl. Entri(belum diset)
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.