Judul ArtikelSTUDI ANALISIS ARUS SIRKULASI PADA INVERTER 1 FASA YANG BEROPERASI PARALEL DENGAN TRAFO
Abstrak (Bhs. Indonesia)Penelitian ini bertujuan menganalisis karakteristik arus sirkulasi pada operasi paralel inverter satu fasa Voltage Source Inverter (VSI) dan Current Source Inverter (CSI) menggunakan transformator melalui simulasi pada perangkat lunak PSIM. Pengujian dilakukan dengan memvariasikan parameter arus referensi (Iref) sebesar 1–20 A, sudut fasa 0°–20°, frekuensi 45–55 Hz, dead time 1–5 µs, dan overlap time 1–5 µs untuk mengetahui pengaruhnya terhadap arus sirkulasi dan efisiensi sistem. Hasil simulasi menunjukkan bahwa peningkatan perbedaan parameter operasi antara kedua inverter menyebabkan kenaikan arus sirkulasi. Pada pengujian variasi frekuensi dengan VSI tetap 50 Hz dan CSI dinaikkan dari 50 Hz menjadi 54 Hz, arus sirkulasi meningkat dari 0,2696 A menjadi 2,5217 A. Pada pengujian variasi arus referensi diperoleh bahwa saat Iref CSI tetap 5 A dan Iref VSI 10 A, arus sirkulasi sebesar 2,02 A, sedangkan saat Iref VSI tetap 5 A dan Iref CSI 10 A, arus sirkulasi sebesar 1,22 A, menunjukkan bahwa perubahan arus referensi pada VSI memberikan pengaruh yang lebih besar terhadap arus sirkulasi dibandingkan perubahan pada CSI. Selain itu, efisiensi sistem berada pada kisaran 89–98% bergantung pada variasi parameter yang digunakan. Hasil penelitian menunjukkan bahwa kesesuaian parameter operasi antara inverter VSI dan CSI mampu menekan arus sirkulasi, meningkatkan efisiensi, serta menghasilkan operasi paralel yang lebih stabil
Abtrak (Bhs. Inggris)This study aims to analyze the characteristics of circulating current in the parallel operation of single-phase Voltage Source Inverter (VSI) and Current Source Inverter (CSI) using a transformer through simulation in PSIM software. The simulations were conducted by varying the reference current (Iref) from 1 A to 20 A, phase angle from 0° to 20°, frequency from 45 Hz to 55 Hz, dead time from 1 μs to 5 μs, and overlap time from 1 μs to 5 μs to investigate their effects on circulating current and system efficiency. The simulation results indicate that increasing the mismatch in operating parameters between the two inverters leads to a higher circulating current. In the frequency variation test, with the VSI frequency fixed at 50 Hz and the CSI frequency increased from 50 Hz to 54 Hz, the circulating current increased from 0.2696 A to 2.5217 A. In the reference current variation test, when the CSI reference current was maintained at 5 A and the VSI reference current was increased to 10 A, the circulating current reached 2.02 A.. Furthermore, the system efficiency ranged from 89% to 98%, depending on the operating conditions. The results demonstrate that maintaining compatible operating parameters between the VSI and CSI effectively reduces circulating current, improves system efficiency, and enhances the stability of parallel inverter operation
Kata kunciCSI, VSI, Operasi Paralel, H- Bridge, Arus Sirkulasi
Pembimbing 1Prof. Dr. Eng. Ir. Suroso S.T., M.Eng. IPU
Pembimbing 2Ir. Winasis S.T, M.Eng
Pembimbing 3
Tahun2026
Jumlah Halaman17
Tgl. Entri2026-08-14 19:39:40.749116
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.