Artikel Ilmiah : H1A022002 a.n. FERDI SATRIA NUGRAHA

Kembali Update Delete

NIMH1A022002
NamamhsFERDI SATRIA NUGRAHA
Judul ArtikelANALISIS INVERTER H-BRIDGE CSI TERHUBUNG GRID AC DENGAN TRAFO
Abstrak (Bhs. Indonesia)Penelitian Kualitas daya pada Current Source Inverter (CSI) yang terhubung ke grid dipengaruhi oleh distorsi harmonisa dan sinkronisasi dengan jaringan, sehingga diperlukan transformator untuk meningkatkan performa sistem. Penelitian ini bertujuan menganalisis pengaruh penggunaan transformator terhadap kualitas daya inverter H-Bridge CSI yang terhubung grid AC. Metode yang digunakan meliputi simulasi menggunakan PSIM dan Proteus serta implementasi prototipe dengan kontrol PI, SPWM unipolar, dan PLL. Pengujian dilakukan dengan memvariasikan arus referensi sebesar 2–12 A untuk menganalisis karakteristik arus, tegangan, THD, dan faktor daya. Hasil simulasi menunjukkan bahwa penggunaan transformator mampu menjaga THD arus grid pada kisaran 0,60–3,20% dengan faktor daya sebesar 1, sedangkan tanpa transformator THD arus inverter dan arus grid meningkat hingga 45,71% dan 44,31%. Implementasi prototipe belum beroperasi optimal akibat kegagalan rangkaian driver menghasilkan gate signal yang sesuai. Hasil penelitian menunjukkan bahwa transformator efektif meningkatkan kualitas daya inverter CSI yang terhubung grid.
Abtrak (Bhs. Inggris)Power quality in a grid-connected Current Source Inverter (CSI) is affected by harmonic distortion and synchronization with the utility grid. This study aims to analyze the effect of a transformer on the power quality of a single-phase H-Bridge CSI. The research was conducted through PSIM and Proteus simulations and prototype implementation using PI control, unipolar SPWM, and a PLL. The reference current was varied from 2 A to 12 A to evaluate current, voltage, Total Harmonic Distortion (THD), and power factor. The simulation results show that the transformer maintained grid current THD within 0.60–3.20% with a unity power factor, whereas under transformerless operation, the inverter and grid current THD increased to 45.71% and 44.31%, respectively. The prototype could not operate properly due to the driver circuit failing to generate the required gate signals. The results demonstrate that the transformer effectively improves the power quality of a grid-connected CSI.
Kata kunciCurrent Source Inverter (CSI), H-Bridge, Transformator, Grid-Connected, THD, Faktor Daya
Pembimbing 1Prof. Dr. Eng. Ir. Suroso, S.T., M.Eng., IPU.
Pembimbing 2Ir. Winasis, S.T., M.Eng.
Pembimbing 3
Tahun2026
Jumlah Halaman19
Tgl. Entri2026-08-14 19:24:54.263419
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.