| Judul Artikel | Analisis Dosis Radiasi CT Angiografi Kepala Berdasarkan Diagnostic Reference Level dan Body Mass Index di RSUD Prof. Dr. Margono Soekarjo |
| Abstrak (Bhs. Indonesia) | CT Angiografi (CTA) kepala merupakan metode pencitraan yang memanfaatkan radiasi sinar-X untuk mendiagnosis kelainan pembuluh darah kepala. Salah satu faktor yang dapat memengaruhi dosis radiasi adalah Body Mass Index (BMI). Penelitian ini bertujuan menganalisis nilai Diagnostic Reference Level (DRL) serta hubungan antara BMI dan dosis radiasi. Penelitian ini melibatkan 30 pasien berusia 19–74 tahun yang menjalani pemeriksaan CTA kepala di RSUD Prof. Dr. Margono Soekarjo Purwokerto. Data yang dikumpulkan meliputi tinggi badan, berat badan, CTDIvol, dan DLP. Hasil penelitian diperoleh nilai DRL lokal (Q2) untuk CTDIvol dan DLP masing-masing sebesar 14,05 mGy dan 1320,84 mGy.cm, sedangkan DRL nasional (Q3) sebesar 16,22 mGy dan 1561,19 mGy.cm. Nilai rata-rata CTDIvol pada pasien dengan BMI normal, overweight, dan obesitas masing-masing sebesar 12,60±0,67 mGy; 15,20±2,82 mGy; dan 18,02±3,66 mGy, DLP sebesar 1119,33±92,77 mGy.cm; 1547,63±394,63 mGy.cm; dan 1656,79±478,41 mGy.cm, serta dosis efektif sebesar 3,47±0,29 mSv; 4,80±1,22 mSv; dan 5,14±1,48 mSv. Hasil menunjukkan bahwa nilai DRL nasional (Q3) berada di bawah standar I-DRL BAPETEN sehingga pemeriksaan CTA kepala yang dilakukan termasuk aman. Selain itu, rata-rata dosis radiasi cenderung meningkat seiring meningkatnya BMI pasien. |
| Abtrak (Bhs. Inggris) | Head CT Angiography (CTA) is an imaging method that uses X-rays radiation to diagnose abnormalities in the blood vessels of the head. One of the factors that can influence radiation dose is Body Mass Index (BMI). This study aims to analyze the Diagnostic Reference Level (DRL) values and the relationship between BMI and radiation dose. This study involved 30 patients aged 19–74 years who underwent head CTA examinations at Prof. Dr. Margono Soekarjo Purwokerto Regional General Hospital. The data collected included height, weight, CTDIvol, and DLP. The study results yielded the local DRL (Q2) values for CTDIvol and DLP were 14.05 mGy and 1320.84 mGy.cm, respectively, while the national DRL (Q3) values were 16.22 mGy and 1561.19 mGy.cm. The average CTDIvol values for patients with normal BMI, overweight, and obesity were 12.60±0.67 mGy, 15.20±2.82 mGy, and 18.02±3.66 mGy, respectively, the DLP values were 1119.33±92.77 mGy.cm, 1547.63±394.63 mGy.cm; and 1656.79±478.41 mGy.cm, and the effective doses were 3.47±0.29 mSv; 4.80±1.22 mSv; and 5.14±1.48 mSv. This study showed that the national DRL (Q3) value is below the I-DRL BAPETEN standard, so the head CTA examinations conducted are safe. Additionally, the average radiation dose tends to increase as the patient’s BMI increases. |
| Kata kunci | CT Angiografi kepala, Body Mass Index (BMI), Diagnostic Reference Level (DRL), dosis radiasi |
| Pembimbing 1 | Prof. Dr. Bilalodin, S.Si., M.Si. |
| Pembimbing 2 | Prof. Dr. Eng. Mukhtar Effendi, S.Si., M.Eng. |
| Pembimbing 3 | |
| Tahun | 2026 |
| Jumlah Halaman | 71 |
| Tgl. Entri | 2026-05-13 12:21:00.526134 |
|---|