Judul ArtikelPeningkatan Selektivitas Metode Analisis Amoksisilin dalam Suspensi Amokisisilin Menggunakan Spektrofotometri UV
Abstrak (Bhs. Indonesia)Pengukuran kadar amoksisilin dalam suspensi amoksisilin pada kisaran 291 nm diduga memberikan hasil yang lebih akurat, selektif dan tidak dipengaruhi keberadaan produk degradasinya. Penelitian ini bertujuan mengetahui selektivitas, keakuratan, dan prosedur pengukuran kadar amoksisilin dalam suspensi amoksisilin pada kisaran panjang gelombang 291 nm.

Penelitian ini dilakukan dengan metode eksperimental laboratorium meliputi penentuan panjang gelombang maksimum dan operating time, pembuatan kurva baku dengan mengukur serapan larutan amoksisilin stándar 40, 50, 80, 100 dan 120 ppm pada 290 nm, pengujian selektivitas dan akurasi metode analisis. Pengujian selektivitas dilakukan dengan membandingkan spektrum UV dan nilai absorbansi amoksisilin standar 1 mg/mL dan suspensi amoksisilin 125 mg/5 mL sesaat setelah direkonstitusi dengan yang sudah disimpan 9 hari. Pengujian akurasi dilakukan dengan stándar addition method pada 1 mL suspensi amoksisilin yang sudah disimpan 9 hari ditambah 1 mL larutan amoksisilin stándar 6260 ppm.

Pengukuran kadar amoksisilin dalam suspensi amoksisilin menggunakan metode spektrofotometri UV pada 290 nm dalam rentang waktu pengukuran 77 menit memberikan hasil yang akurat dengan perolehan kembali 97,37% dan selektif tanpa dipengaruhi keberadaan produk degradasinya.
Abtrak (Bhs. Inggris)Measurement of amoxicillin on suspension form at 291 nm supposedly gives more accurate, selective result and not influenced by the presence of its degradation products. The objective of this study is determine selectivity, accuracy and measurement procedures amoxicillin in amoxicillin suspensions at around 291 nm.

This research was conducted by laboratory experimental method covered determining the maximum wavelength and the operating time, making calibration curve by measuring the absorption of 40, 50, 80, 100 and 120 ppm amoxicillin standard solution, selectivity and accuracy. Selectivity testing was done by comparing the UV spectrum and the absorbance value at amoxicillin standard solution 1 mg / mL and amoxicillin suspension 125 mg / 5 mL immediately after reconstitution with that was stored for 9 days. Accuracy testing was done by standard addition method using 1 mL amoxicillin suspension which was stored for 9 days enrich with 1 mL of amoxicillin standard of 6260 ppm.

Measurement of amoxicillin in amoxicillin suspensions using UV spectrophotometry at 290 nm within 77 minutes span measurements provide accurate and selective results with 97.37% recovery and not be interfered the influenced by its degradation products.
Kata kunciamoksisilin, asam penamaldat, selektivitas, accuracy, spektrofotometri UV
Pembimbing 1Rehana, M.Si., Apt
Pembimbing 2Vitis Vini Fera RU, M.Sc., Apt
Pembimbing 3
Tahun2013
Jumlah Halaman10
Tgl. Entri(belum diset)
Cetak Bukti Unggah