Artikel Ilmiah : B1B018043 a.n. MUHAMMAD FUAD FAJRUSHOBAH

Kembali Update Delete

NIMB1B018043
NamamhsMUHAMMAD FUAD FAJRUSHOBAH
Judul ArtikelMEASUREMENT OF ORGANIC WASTE WATER TREATMENT IN THE CROCODILE CAPTIVITY, DAWUHAN KULON VILLAGE, KEDUNGBANTENG SUBDISTRICT, BANYUMAS REGENCY
Abstrak (Bhs. Indonesia)Fasilitas penangkaran buaya di Desa Dawuhan Kulon, Kecamatan Kedungbanteng, Kabupaten Banyumas menghasilkan air limbah yang berpotensi mencemari lingkungan sekitarnya. Meskipun pengelolaan fasilitas tersebut telah sesuai dengan peraturan yang berlaku, pembuangan limbah domestik yang belum diolah ke badan air dapat menurunkan kualitas perairan akibat tingginya kandungan organik, bakteri coliform, serta padatan terlarut. Kondisi ini menimbulkan risiko bagi kesehatan masyarakat, ekosistem perairan, dan keberlanjutan konservasi. Untuk meminimalisasi dampak tersebut, dibangun Instalasi Pengolahan Air Limbah (IPAL) berbasis biofilter sebagai sistem pengendalian pencemaran.

Tujuan penelitian ini adalah untuk menilai kualitas air limbah setelah pengolahan menggunakan biofilter serta menganalisis efektivitas sistem dalam menurunkan parameter pencemar utama. Penelitian dilaksanakan dengan metode survei menggunakan purposive sampling pada titik inlet dan outlet IPAL, dengan total 24 sampel air masing-masing sebanyak 1 liter. Parameter utama yang diukur meliputi Biochemical Oxygen Demand (BOD₅), Total Dissolved Solids (TDS), dan Most Probable Number (MPN) coliform, sedangkan parameter pendukung berupa pH, suhu, dan Total Plate Count (TPC). Analisis data dilakukan dengan menghitung nilai rata-rata, perbedaan antara inlet dan outlet, serta efisiensi pengolahan, kemudian dibandingkan dengan baku mutu lingkungan. Efektivitas biofilter diuji lebih lanjut menggunakan IBM SPSS dengan analisis ANOVA (uji t berpasangan), didukung interpretasi dari parameter sekunder.

Hasil penelitian menunjukkan bahwa sistem biofilter mampu menurunkan MPN sebesar 30,2%, yang mengindikasikan efektivitas sedang dalam mengurangi mikroorganisme patogen. Sebaliknya, nilai BOD₅ meningkat dari 2,2 menjadi 2,4 mg/L dengan efisiensi negatif sebesar -9,1%, dan TDS naik dari 67,6 menjadi 70,3 mg/L dengan efisiensi negatif sebesar -3,9%. Temuan ini mengonfirmasi bahwa sistem biofilter kurang efektif dalam menurunkan bahan organik dan padatan terlarut, sehingga diperlukan perbaikan dengan teknologi lanjutan seperti reverse osmosis, nanofiltrasi, atau membran bioreaktor.

Selain itu, parameter pendukung memperkuat hasil tersebut. Nilai pH sedikit bergeser menuju netral (7,82 menjadi 7,96) dan suhu relatif stabil (25,96 °C menjadi 25,79 °C), keduanya mendukung aktivitas mikroba. Yang paling signifikan, jumlah Total Plate Count (TPC) menurun drastis dari 150,2 × 10⁴ menjadi 38,1 × 10⁴ CFU/mL, yang menegaskan kemampuan sistem dalam mengurangi kontaminasi mikroba.

Secara keseluruhan, meskipun biofilter menunjukkan potensi dalam menurunkan beban mikroba, optimalisasi lebih lanjut masih diperlukan agar kinerjanya dapat ditingkatkan dalam menurunkan bahan organik maupun padatan terlarut.
Abtrak (Bhs. Inggris)The crocodile captivity facility in Dawuhan Kulon Village, Kedungbanteng The crocodile captivity in Dawuhan Kulon Village, Kedungbanteng District, Banyumas Regency generates wastewater that has the potential to pollute the surrounding environment. Although the facility is managed in accordance with existing regulations, untreated domestic wastewater discharged into water bodies can decrease water quality due to high organic content, coliform bacteria, and dissolved solids. This condition poses risks to public health, aquatic ecosystems, and conservation sustainability. To mitigate these impacts, a biofilter-based Wastewater Treatment Plant (WWTP) was constructed as a pollution control system.The aim of this study was to assess the quality of wastewater after biofilter treatment and to analyze the effectiveness of the system in reducing key pollutants. The research was conducted using a survey method with purposive sampling at the inlet and outlet of the WWTP, resulting in 24 water samples of 1 liter each. The main parameters measured were Biochemical Oxygen Demand (BOD₅), Total Dissolved Solids (TDS), and Most Probable Number (MPN) of coliforms, while pH, temperature, and Total Plate Count (TPC) were analyzed as supporting parameters. Data analysis included calculating mean values, inlet–outlet differences, and treatment efficiency, which were then compared with the environmental quality standards. The effectiveness of the biofilter was further tested using IBM SPSS with ANOVA (paired t-test), supported by the interpretation of secondary parameters.The results showed that the biofilter system reduced MPN by 30.2%, indicating moderate effectiveness in lowering pathogenic microorganisms. In contrast, BOD₅ increased from 2.2 to 2.4 mg/L with a negative efficiency of -9.1%, and TDS rose from 67.6 to 70.3 mg/L with a negative efficiency of -3.9%. These findings confirm that the system was less effective for organic matter and dissolved solids, and further improvements with advanced technologies such as reverse osmosis, nanofiltration, or membrane bioreactors are required. In addition, supporting parameters supported these results. The pH shifted slightly toward neutrality (7.82 to 7.96) and temperature remained stable (25.96 °C to 25.79 °C), both favorable for microbial activity. Most notably, the Total Plate Count (TPC) decreased substantially from 150.2 × 10⁴ to 38.1 × 10⁴ CFU/mL, reinforcing the system’s capacity to reduce microbial contamination. Overall, while the biofilter showed promise in lowering microbial loads, further optimization is necessary to improve its performance in reducing organic matter and dissolved solids.
Kata kunciBOD, Biofilter, Bioremediation, Crocodile breeding, MPN.
Pembimbing 1Dr. Sri Lestari, S.Si., M.Si.
Pembimbing 2Prof. Dr. Oedjijono, M.Sc.
Pembimbing 3
Tahun2025
Jumlah Halaman6
Tgl. Entri2025-08-21 10:24:26.958816
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.