Artikel Ilmiah : H1A020073 a.n. BAGAS DUTA RESPATTY

Kembali Update Delete

NIMH1A020073
NamamhsBAGAS DUTA RESPATTY
Judul Artikel ANALISIS KINERJA BATERAI PADA AXIS TURBIN ANGIN UNIT 1
KOTA HOUHOKUCHO, PERFEKTUR YAMAGUCHI,
CLEAN ENERGY FACTORY CO., LTD.
Abstrak (Bhs. Indonesia) Penelitian ini bertujuan untuk menganalisis kinerja baterai yang
digunakan dalam sistem pitch control pada turbin angin horizontal (horizontal
axis wind turbin) Unit 1 yang terletak di Kota Houhokucho, Prefektur Yamaguchi,
milik CLEAN ENERGY FACTORY Co.,Ltd. Baterai pada sistem ini tidak
berfungsi sebagai penyimpan energi listrik hasil pembangkitan, melainkan
digunakan secara khusus untuk menggerakkan bilah turbin melalui sistem pitch
kontrol berbasis elektrik.
Analisis dilakukan berdasarkan parameter teknis baterai seperti
kapasistas, tegangan, arus, dan daya tahan, serta mempertimbangkan kondisi
lingkungan seperti suhu, kelembaban, dan kecepatan angin. Selain itu, dibahas
pula pola penggunaan baterai dalam pengoperasian turbin serta beban daya yang
diberikan oleh sistem pitch kontrol terhadap baterai. Penelitian ini diharapkan
dapat memberikan gambaran tentang efisiensi dan ketahanan baterai dalam
kondisi operasional sebenarnya dan menjadi bahan pertimbangan dalam
pengelolaan pemeliharaan turbin.
Abtrak (Bhs. Inggris) This study aims to analyze the perfomance of batteries used in the pitch
control system of the horizontal axis wind turbin (HAWT) unit 1 located in
Houhokucho City, Yamaguchi Prefecture, owned by CLEAN ENERGY FACTORY
Co.,Ltd. The battery in this system does not serve as an energy storage for
generated electricity but is specifically used to operate the turbine blades through
a fully electric pitch control mechanism.
The analysis is conducted based on technical parameters of the battery
such as capacity, voltage, current, and durability, while also taking into account
enviromental conditions such as temperature, humidity, and wind speed. In
addition, the study discusses the usage pattern of the battery during turbine
operation and the electrical load imposed by the pitch system. The results are
expected to provide insight into the battery’s efficiency and endurance under
actual operating conditions and to support maintenance planning for wind turbine
systems.
Kata kunciKata kunci : Turbin Angin, Pitch kontrol, baterai, Axis horizontal, daya tahan.