| Judul Artikel | ANALISIS PENGARUH PEMBEBANAN TERHADAP EFISIENSI TRANSFORMATOR UNIT 1&2 DI PLTA TULIS |
| Abstrak (Bhs. Indonesia) | Pembangkit Listrik Tenaga Air (PLTA) merupakan sumber energi terbarukan yang berperan penting dalam sistem ketenagalistrikan nasional. Transformator dalam PLTA berfungsi menaikkan tegangan output generator, namun efisiensinya sangat dipengaruhi oleh kondisi pembebanan. Beban yang tidak optimal dapat menimbulkan rugi daya seperti rugi tembaga dan rugi inti, sehingga menurunkan efisiensi sistem. Penelitian ini menganalisis pengaruh pembebanan terhadap efisiensi transformator Unit 1 dan Unit 2 di PLTA Tulis, berdasarkan data logsheet Desember 2024. Perhitungan mencakup daya semu, rugi-rugi, dan efisiensi transformator. Hasil menunjukkan efisiensi meningkat seiring bertambahnya beban hingga titik optimal, lalu menurun. Efisiensi teoritis maksimum Unit 1 sebesar 99,44% pada beban 52,03%, dan Unit 2 sebesar 99,43% pada beban 35–45%. Efisiensi aktual Unit 1 berkisar antara 95,00%–95,72%, sedangkan Unit 2 antara 92,67%–95,69%. Selisih antara nilai ideal dan aktual menunjukkan pentingnya pengelolaan beban yang optimal untuk menjaga kinerja sistem transformator di lapangan. |
| Abtrak (Bhs. Inggris) | Hydroelectric Power Plant (PLTA) is a renewable energy source that plays an important role in the national electricity system. The transformer in a PLTA functions to increase the generator output voltage, but its efficiency is greatly influenced by loading conditions. Suboptimal loads can cause power losses such as copper losses and core losses, thereby reducing system efficiency. This study analyzes the effect of loading on the efficiency of transformers Unit 1 and Unit 2 at the Tulis PLTA, based on logsheet data from December 2024. The calculation includes apparent power, losses, and transformer efficiency. The results show that efficiency increases with increasing load to the optimal point, then decreases. The maximum theoretical efficiency of Unit 1 is 99.44% at a load of 52.03%, and Unit 2 is 99.43% at a load of 35–45%. The actual efficiency of Unit 1 ranges from 95.00%–95.72%, while Unit 2 is between 92.67%–95.69%. The difference between ideal and actual values shows the importance of optimal load management to maintain the performance of transformer systems in the field. |
| Kata kunci | Transformator, Efisiensi,Pembebanan, PLTA Tulis,Rugi-rugi Daya |
| Pembimbing 1 | Ir.Winasis, S.T.,M.Eng. |
| Pembimbing 2 | Hari Prasetijo. S.T., M.T. |
| Pembimbing 3 | |
| Tahun | 2025 |
| Jumlah Halaman | 12 |
| Tgl. Entri | 2025-07-17 12:07:19.193515 |