Artikel Ilmiah : K1C021024 a.n. AYU LISRIANTI

Kembali Update Delete

NIMK1C021024
NamamhsAYU LISRIANTI
Judul ArtikelANALISIS KUALITAS CITRA PADA PEMERIKSAAN CT CARDIAC DI INSTALASI RADIOLOGI ABIYASA RSUD. Prof. Dr. MARGONO SOEKARJO PURWOKERTO
Abstrak (Bhs. Indonesia)Penyakit Jantung Koroner (PJK) merupakan penyebab utama kematian global, sehingga diperlukan metode diagnostik yang akurat untuk mendukung penanganan medis. CT Cardiac menjadi salah satu teknologi pencitraan non-invasif yang dapat memvisualisasikan struktur jantung dan pembuluh darah koroner secara detail. Namun, kualitas citra CT dipengaruhi oleh beberapa faktor seperti scan delay, indeks massa tubuh (IMT), heart rate, dan tekanan darah. Penelitian ini bertujuan untuk menganalisis citra terbaik dan menentukan pengaruh faktor-faktor terhadap kualitas citra CT Cardiac menggunakan software IndoQCT. Data diperoleh dari 20 pasien dengan pemeriksaan CT Cardiac pada kasus PJK di RSUD Prof. Dr. Margono Soekarjo Purwokerto. Parameter kualitas citra dievaluasi berdasarkan nilai Signal-to-Noise Ratio (SNR) dan Contrast-to-Noise Ratio (CNR). Pemeriksaan CT Cardiac dilakukan dengan teknik khusus menggunakan alat EKG Trigger dan media kontras, yang menghasilkan citra jantung dengan visualisasi optimal terhadap struktur pembuluh darah koroner, termasuk gambaran kalsifikasi atau penyumbatan yang memengaruhi aliran darah. Hasil analisis menunjukkan bahwa nilai SNR dan CNR tertinggi diperoleh pada Pasien 12, sedangkan nilai terendah terdapat pada Pasien 6. Seluruh nilai yang diperoleh tetap memenuhi standar BAPETEN (>1), sehingga dikategorikan baik. Peningkatan nilai scan delay, heart rate, dan tekanan darah cenderung menurunkan nilai SNR dan CNR, sedangkan peningkatan Indeks Massa Tubuh (IMT) memberikan pengaruh sebaliknya. Faktor-faktor tersebut berkontribusi terhadap perubahan densitas kalsifikasi pada pembuluh darah koroner.
Abtrak (Bhs. Inggris)Coronary Angiography Disease (CAD) is the leading cause of death globally, so accurate diagnostic methods are needed to support medical treatment. Cardiac CT is one of the non-invasive imaging technologies that can visualize the structure of the heart and coronary blood vessels in detail. However, CT image quality is affected by several factors such as scan delay, body mass index (BMI), heart rate, and blood pressure. This study aims to analyze the influence of these factors on the quality of Cardiac CT images using IndoQCT software. Data were obtained from 20 patients with CT Cardiac examination in CAD cases at RSUD Prof. Dr. Margono Soekarjo Purwokerto. Image quality parameters were evaluated based on Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) values. Cardiac CT examination is performed with a special technique using ECG Trigger and contrast media, which produces heart images with optimal visualization of the structure of the coronary blood vessels, including images of calcifications or blockages that affect blood flow. The analysis showed that the highest SNR and CNR values were obtained in Patient 12, while the lowest values were obtained in Patient 6. All values obtained still meet BAPETEN standards (>1), so they are categorized as good. An increase in scan delay, heart rate, and blood pressure tends to decrease SNR and CNR values, while an increase in Body Mass Index (BMI) has the opposite effect. These factors contribute to changes in calcification density in coronary blood vessels.
Kata kunciCT Cardiac, Kualitas Citra, SNR, CNR, Scan Delay, IMT, Heart Rate, Tekanan Darah
Pembimbing 1Prof. Dr. Bilalodin, S.Si., M.Si.
Pembimbing 2Agus Sholeh, S.Si.
Pembimbing 3
Tahun2025
Jumlah Halaman74
Tgl. Entri2025-05-14 17:46:36.644947
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.