Judul ArtikelOPTIMASI TEGANGAN DAN ARUS WAKTU PADA
BERBAGAI KETEBALAN PHANTOM ABDOMEN DEWASA
UNTUK MENDAPATKAN KUALITAS CITRA TERBAIK
Abstrak (Bhs. Indonesia)Penggunaan sinar-X dalam bidang medis sangat penting untuk diagnosis, namun berpotensi menimbulkan risiko kesehatan akibat paparan radiasi. Oleh karena itu,
penelitian ini bertujuan untuk mengoptimalkan tegangan dan arus waktu pada
pemeriksaan radiografi abdomen dewasa menggunakan phantom akrilik-aluminium dengan ketebalan 14 cm dan 16 cm dengan variasi tegangan yang
diterapkan berkisar antara 61-85 kVp, sementara arus waktu divariasikan pada
12,6 mAs, 16 mAs, dan 20 mAs. Kualitas citra dievaluasi melalui analisis
Contrast to Noise Ratio (CNR) dan resolusi spasial menggunakan perangkat lunak
Phantom Image Automatic Acquisition and Analysis (PIAAA). Hasil penelitian
menunjukkan bahwa peningkatan tegangan dan arus waktu berbanding lurus
dengan kegelapan citra yang dihasilkan karena dipengaruhi oleh kontras dan
densitas radiograf. Berdasarkan nilai CNR dan resolusi spasial, nilai optimal
tegangan dan arus waktu pada ketebalan 14 cm diperoleh pada tegangan 73 kVp
dan arus waktu 16 mAs, sedangkan pada ketebalan 16 cm, nilai optimal pada
tegangan 79 kVp dan arus waktu 16 mAs. Ketebalan phantom yang lebih tinggi
memerlukan tegangan yang lebih tinggi untuk mempertahankan kualitas citra.
Abtrak (Bhs. Inggris)The use of X-rays in the medical field is crucial for diagnosis, but it also poses
potential health risks due to radiation exposure. There fore, this study aims to
optimize the voltage and exposure time during adult abdominal radiography
examinations using acrylic-aluminum phantoms with thicknesses of 14 cm and 16
cm. The applied voltage varied between 61-85 kVp, while the exposure time was
varied at 12.6 mAs, 16 mAs, and 20 mAs. Image quality was evaluated through
Contrast to Noise Ratio (CNR) analysis and spatial resolution using the Phantom
Image Automatic Acquisition and Analysis (PIAAA) software. The results
indicated that increases in voltage and exposure time were directly proportional
to the darkness of the resulting images, influenced by contrast and radiographic
density. Based on CNR values and spatial resolution, the optimal voltage and
exposure time for the 14 cm thickness were found to be 73 kVp and 16 mAs, while
for the 16 cm thickness, the optimal values were 79 kVp and 16 mAs. A higher
phantom thickness requires a higher voltage to maintain image quality.
Kata kunciTegangan, Arus Waktu, Contrast to Noise Ratio (CNR), Resolusi Spasial, Phantom Abdomen, Kualitas Radiografi.