Judul ArtikelSIMULASI DISTRIBUSI SUHU UDARA PADA APLIKASI COOLING PAD GREENHOUSE TIPE PIGGYBACK MENGGUNAKAN COMPUTATIONAL FLUID DYNAMICS
Abstrak (Bhs. Indonesia)Greenhouse tipe piggyback merupakan salah satu greenhouse sistem ventilasi udaranya jauh lebih adaptif terhadap iklim mikro sebab dilengkapi struktur bukaan yang memungkinkan sirkulasi udara pada greenhouse lebih baik. Namun ketika ventilasi alami pada greenhouse tipe piggyback tidak mampu menurunkan suhu sesuai kebutuhan tanaman maka diperlukan pengendalian mekanik, salah satunya dengan cooling pad. Salah satu aplikasi yang dapat digunakan untuk memprediksi sebaran suhu yakni dengan aplikasi CFD (Computational Fluid Dynamics). CFD merupakan analisis berbasis komputer yang dapat mensimulasi keadaan aliran fluida, pindah panas dan massa. Penelitian dilakukan dengan mengukur variabel iklim mikro yang meliputi suhu, intensitas cahaya dan kelembapan udara pada greenhouse. Data tersebut dianalisis menggunakan CFD mendapatkan pola distribusi suhu udara pada greenhouse tipe piggyback. Analisis CFD meliputi tiga tahap, yaitu pra pemrosesan, pencarian masalah, pasca pemrosesan yang akan menghasilkan validasi dalam bentuk nilai eror dari hasil simulasi. Hasil dari penelitian menunjukan bahwa suhu di dalam greenhouse tipe piggyback berkisar 32,1 – 36,7°C pada saat cooling pad menyala dan pada tanpa cooling pad menunjukan suhu berkisar 34,7 – 38,5°C . Pada hasil simulasi menunjukan distribusi suhu pada greenhouse tipe piggyback berteknologi cooling pad berhasil dilakukan dan menghasilkan prediksi sekitar 33,7 – 37,3°C dari suhu awal 35,1 – 38,5°C dengan suhu cooling pad sebesar 32,1°C. Pola distribusi ditampilkan dalam bentuk kontur warna dan vektor, dimana pada simulasi menit ke-5 terjadi perubahan kontur warna dan vektor yang menunjukkan adanya penurunan suhu dalam greenhouse. Berdasakan hasil simulasi CFD sistem cooling pad diprediksi mampu menurunkan suhu greenhouse hingga 1,2 – 1,4°C dari nilai awal. Nilai validasi dihitung menggunakan rumus persentase error nilai suhu simulasi terhadap nilai suhu actual yang diukur pada 10 titik di dalam greenhouse dan diperoleh sebesar 5,19%.
Abtrak (Bhs. Inggris)The piggyback type greenhouse is one of the greenhouses with an air ventilation system that is much more adaptive to the microclimate because it is equipped with an opening structure that allows better air circulation in the greenhouse. However, when natural ventilation in a piggyback type greenhouse is unable to lower the temperature according to plant needs, mechanical control is needed, one of which is a cooling pad. One application that can be used to predict temperature distribution is the CFD (Computational Fluid Dynamics) application. CFD is a computer-based analysis that can simulate fluid flow conditions, heat and mass transfer. The research was carried out by measuring microclimate variables which include temperature, light intensity and air humidity in the greenhouse. This data was analyzed using CFD to obtain the air temperature distribution pattern in the piggyback type greenhouse. CFD analysis includes three stages, namely pre-processing, problem finding, post-processing which will produce validation in the form of error values from the simulation results. The results of the research show that the temperature in the piggyback type greenhouse ranges from 32.1 – 36.7°C when the cooling pad is on and without the cooling pad the temperature ranges from 34.7 – 38.5°C. The simulation results show that the temperature distribution in the piggyback type greenhouse with cooling pad technology was successfully carried out and produced predictions of around 33.7 – 37.3°C from the initial temperature of 35.1 – 38.5°C with a cooling pad temperature of 32.1°C . The distribution pattern is displayed in the form of color contours and vectors, where in the 5th minute of the simulation there is a change in the color contour and vector which indicates a decrease in temperature in the greenhouse. Based on the CFD simulation results, the cooling pad system is predicted to be able to reduce the greenhouse temperature by 1.2 – 1.4°C from the initial value. The validation value was calculated using the formula for the percentage error of the simulated temperature value to the actual temperature value measured at 10 points in the greenhouse and was obtained at 5.19%.
Kata kunciCFD, greenhouse, simulasi, distribusi suhu, cooling pad
Pembimbing 1Dr. Eni Sumarni, S.TP., M.Si.
Pembimbing 2Dr. Asna Mustofa, S.TP., M.P.
Pembimbing 3
Tahun2024
Jumlah Halaman11
Tgl. Entri2024-05-16 12:24:23.871512
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.