Judul ArtikelOptimasi Citra CT-Scan Pada Pasien Kanker Hepar Dengan Media Kontras Ditambahkan Saline Flush Menggunakan Metode Modulation Transfer Function (MTF)
Abstrak (Bhs. Indonesia)CT-scan merupakan alat diagnostik untuk menentukan anatomi dan kelainan dalam tubuh. Pemeriksaan CT-Scan dengan menggunakan media kontras dianggap mampu meningkatkan ketajaman, Media kontras cenderung menyebar ke pembuluh sehingga diperlukan saline flush untuk mendorong media kontas untuk mencapai lokasi kanker. Perhitungan kualitas citra pada resolusi spasial dapat menggunakan metode MTF dengan Software IndoQCT. Nilai MTF pada indoQCT didapatkan melalui 4 tahap yaitu input citra, ROI atau Cropping, LSF dan MTF. Pemeriksaan CT-Scan pasien kanker hepar ada tiga fase yaitu fase arteri, vena dan delayed. Menurut BAPETEN standar nilai MTF 10% yaitu > 0,5 lp/mm. Hasil pengolahan Data A diperoleh nilai MTF 10% pada fase arteri, vena dan delayed secara berturut-turut yaitu nilai terendah 0,55 lp/mm, 0,63 lp/mm, 0,62 lp/mm dan nilai tertinggi 1,36 lp/mm, 1,25 lp/mm dan 1,29 lp/mm. Rata-rata nilai MTF 10% pada fase arteri, vena dan delayed berturut turut sebesar 0,84 lp/mm, 0,85 lp/mm dan 0,78 lp/mm. Hasil pengolahan Data B diperoleh nilai MTF 10% pada fase arteri, vena dan delayed secara berturut-turut yaitu nilai terendah 0,52 lp/mm, 0,51 lp/mm dan 0,51 lp/mm dan nilai tertinggi 0,76 lp/mm, 0,85 lp/mm, 0,85 lp/mm. Rata rata nilai MTF 10% pada fase arteri, vena dan delayed berturut turut sebesar 0,61 lp/mm, 0,66 lp/mm, 0,63 lp/mm. Perhitungan nilai MTF 10% mampu menunjukkan fase terbaik (optimal) citra yang dihasilkan dalam pemeriksaan kanker hepar yaitu pada fase vena.
Abtrak (Bhs. Inggris)CT scan is a diagnostic tool to determine anatomy and abnormalities in the body. CT-Scan examination using contrast media is considered capable of increasing sharpness, contrast media tends to spread to the vessels so a saline flush is needed to encourage the converse media to reach the cancer site. Calculation of image quality at spatial resolution can use the MTF method with IndoQCT Software. The MTF value in indoQCT is obtained through 4 stages, namely image input, ROI or Cropping, LSF and MTF. CT-Scan examination of liver cancer patients has three phases, namely arterial, venous and delayed phases. According to BAPETEN, the standard MTF value of 10% is ≥ 0.5 lp/mm. The results of Data A processing obtained MTF values of 10% in the arterial, venous and delayed phases respectively, namely the lowest values of 0.55 lp / mm, 0.63 lp / mm, 0.62 lp / mm and the highest values of 1.36 lp / mm, 1.25 lp / mm and 1.29 lp / mm. The average MTF value of 10% in the arterial, venous and delayed phases was 0.84 lp/mm, 0.85 lp/mm and 0.78 lp/mm, respectively. The results of Data B processing obtained MTF values of 10% in the arterial, venous and delayed phases respectively, namely the lowest values of 0.52 lp / mm, 0.51 lp / mm and 0.51 lp / mm and the highest values of 0.76 lp / mm, 0.85 lp / mm, 0.85 lp / mm. The average MTF value of 10% in the arterial, venous and delayed phases was 0.61 lp/mm, 0.66 lp/mm, 0.63 lp/mm, respectively. The calculation of the MTF value of 10% is able to show the best phase (optimal) image produced in liver cancer examination, namely in the venous phase.


Kata kunciKeywords: CT-Scan, Image Quality, Spatial resolution, Saline flush, Modulation Transfer Function (MTF)
Pembimbing 1Prof. Dr. Bilalodin, S.Si., M.Si
Pembimbing 2Agus Sholeh, S.Si
Pembimbing 3
Tahun2023
Jumlah Halaman18
Tgl. Entri2023-09-01 16:21:28.321548
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.