| Judul Artikel | ANALISIS KOORDINASI SISTEM PROTEKSI OVER CURRENT RELAY, GROUND FAULT RELAY , DAN RECLOSER PADA TRAFO 4 PENYULANG KBL 9 DI GARDU INDUK 150 KV KALIBAKAL PT. PLN (PERSERO) UP3 PURWOKERTO |
| Abstrak (Bhs. Indonesia) | Suatu sistem tenaga listrik pada dasarnya terdiri dari susunan pembangkit, transmisi, dan jaringan distribusi yang terhubung satu sama lain untuk membangkitkan, mentransmisikan, dan mendistribusikan tenaga listrik tersebut hingga dapat dimanfaatkan oleh pelanggan. Karena manfaat dan fungsi sistem tenaga listrik yang sangat vital dalam kehidupan sehari-hari maka diperlukan sistem proteksi yang handal, cepat, selektif, sensitif dan ekonomis. Untuk mencegah kerusakan pada komponen peralatan listrik akibat adanya gangguan maka diperlukan alat untuk mendeteksi adanya gangguan yaitu relay.Pada jaringan distribusi 20 kV untuk mengetahui adanya gangguan terutama gangguan hubung singkat terdapat berbagai macam pengaman/proteksi antara lain Over Current Relay (OCR), Ground Fault Relay (GFR), dan recloser. Untuk mengamankan peralatan dari kerusakan akibat gangguan hubung singkat terutama pada penyulang atau feeder 20 kV maka diperlukan koordinasi proteksi yang baik antara OCR, GFR, dan recloser.Dalam Tugas Akhir ini akan dilakukan analisis koordinasi proteksi OCR, GFR, dan recloser terhadap gangguan hubung singkat pada penyulang KBL 9 karena tercacat terjadi 4 kali gangguan hubung singkat pada penyulang KBL 9 sepanjang tahun 2023. Maka dalam penelitian ini ingin mengkaji kinerja sistem proteksi yang ada pada penyulang KBL 9 untuk meningkatkan kehandalan sistem proteksi pada penyulang tersebut. |
| Abtrak (Bhs. Inggris) | An electric power system basically consists of an arrangement of generation, transmission and distribution networks that are connected to each other to generate, transmit and distribute the electricity so that it can be utilized by customers. Because the benefits and functions of the electric power system are very vital in everyday life, a reliable, fast, selective, sensitive and economical protection system is needed. To prevent damage to electrical equipment components due to disturbances, a device is needed to detect disturbances, namely a relay.In the 20 kV distribution network, to detect disturbances, especially short circuit faults, there are various kinds of safeguards/protections, including Over Current Relay (OCR), Ground Fault Relay (GFR), and recloser. To protect equipment from damage due to short circuit disturbances, especially on 20 kV feeders, good protection coordination is needed between OCR, GFR, and recloser.In this final project, an analysis of the coordination of OCR, GFR, and recloser protection will be carried out for short circuit disturbances in the KBL 9 feeder because it is disabled 4 times for short circuit interruptions in the KBL 9 feeder throughout 2023. So in this study we want to examine the performance of existing protection systems on the KBL 9 feeder to increase the reliability of the protection system on the feeder. |
| Kata kunci | Over Current Relay, Ground Fault Relay, Recloser |
| Pembimbing 1 | Ir. Daru Tri Nugroho, S.T.,M.T |
| Pembimbing 2 | Dr. Mulki Indana Zulfa, S.T.,M.T |
| Pembimbing 3 | |
| Tahun | 2023 |
| Jumlah Halaman | 9 |
| Tgl. Entri | 2023-08-31 09:19:34.270623 |
|---|