Judul ArtikelANALISIS KOORDINASI SISTEM PROTEKSI OVER CURRENT RELAY (OCR), GROUND FAULT RELAY (GFR), DAN RECLOSER TERHADAP GANGGUAN ARUS HUBUNG SINGKAT PADA PENYULANG MRA.02 GARDU INDUK MRICA PT PLN (PERSERO) UP3 PURWOKERTO
Abstrak (Bhs. Indonesia)Pada penyulang MRA.02 telah terjadi trip selama periode 2021 sebanyak 15 kali. Penyulang MRA.02 mempunyai panjang 37,5 km yang terdapat Over Current Relay (OCR) dan Ground Fault Relay (GFR) yang berfungsi untuk memberi perintah kepada recloser dan PMT outgoing. Agar dapat menentukan koordinasi sistem proteksi penyulang yang sesuai maka perlu melakukan perhitungan arus nominal trafo, reaktansi sumber, reaktansi trafo, impedansi, dan arus hubung singkat. Ketika jarak 25% arus sebesar 12845,22 A, dan 10509,72 A, 7225,434 A sedangkan jarak 100% arus sebesar 12802,54 A, 7707,129 A, dan 3124,512 A untuk PMT outgoing, recloser 1, dan recloser 2. Dengan % kesalahan untuk PMT outgoing 0,7%, recloser 1 0,6% dan recloser 2 0,18%. Hasil dari nilai arus hubung singkat digunakan untuk menentukan waktu kerja dan selisih waktu kerja relay antara recloser dan PMT outgoing. Pada setting awal relay memiliki selisih waktu kerja yang tidak sesuai koordinasi, PMT outgoing 0,5 s, recloser 1 0,3 s, dan recloser 2 0,2 detik. Pengaturan ulang nilai TMS relay diperlukan agar sesuai dengan koordinasi proteksi dengan menggunakan waktu kerja baru PMT outgoing 0,7 detik, recloser 1 0,3 detik, dan recloser 2 0,2 detik. Sehingga relai dan recloser bekerja sesuai dengan koordinasi proteksi penyulang yang memenuhi standar PLN dan standar IEC 60255.
Abtrak (Bhs. Inggris)The MRA.02 feeder has made 15 trips during the 2021 period. The MRA.02 feeder has a length of 37.5 km which has Over Current Relay (OCR) and Ground Fault Relay (GFR) which functions to give orders to the recloser and outgoing PMT. In order to determine the appropriate coordination of the feeder protection system, it is necessary to calculate the nominal transformer current, source reactance, transformer reactance, impedance, and short circuit current. When the 25% current distance is 12845.22 A, and 10509.72 A, 7225,434 A while the 100% current distance is 1282.54 A, 7707.129 A, and 3124,512 A for outgoing PMT, recloser 1, and recloser 2. With % error for outgoing PMT 0.7%, recloser 1 0.6% and recloser 2 0.18%. The result of the short circuit current value is used to determine the working time and the difference between the relay working time and the outgoing PMT. In the initial setting, the relay has a working time difference that does not match coordination, PMT outgoing 0.5 s, recloser 1 0.3 s, and recloser 2 0.2 seconds. Resetting the value of the TMS relay is needed to match the coordination of protection by using the new PMT outgoing working time of 0.7 seconds, recloser 1 0.3 seconds, and recloser 2 0.2 seconds. So that the relay and recloser work in accordance with the coordination of feeder protection that meets PLN standards and IEC 60255 standards.
Kata kunciGangguan arus hubung singkat, OCR, GFR, Recloser.
Pembimbing 1Daru Tri Nugroho, S.T., M.T
Pembimbing 2Ari Fadli, ST., M.Eng.
Pembimbing 3
Tahun2022
Jumlah Halaman14
Tgl. Entri2022-07-28 13:28:32.806504
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.