Artikel Ilmiah : L1B017005 a.n. NANDITA IKA QOTHRUNNADA

Kembali Update Delete

NIML1B017005
NamamhsNANDITA IKA QOTHRUNNADA
Judul ArtikelMODULASI SISTEM MONITORING KUALITAS AIR PADA TEKNOLOGI
AKUAPONIK BERBASIS INTERNET OF THINGS (IoT)
Abstrak (Bhs. Indonesia)Aquaponik adalah sistem pertanian berkelanjutan dalam lingkungan
simbiosis dengan menggabungkan akuakultur dan hidroponik. Sistem air ini
harus mengalir pada medium periodik untuk memastikan tanaman
mendapatkan nutrisi, sementara air dapat disaring dengan benar oleh media. Tujuan dari penelitian ini adalah membuat rancang bangun sistem monitoring
kualitas air pada sistem akuaponik berbasis Internet of Things (IoT). Metode
penelitian dilakukan dengan merakit, mengembangkan dan mengintegrasikan
beberapa sensor parameter kualitas air diantaranya pH, suhu, oksigen terlarut
dan amonia. Integrasi sistem ini menggunakan aplikasi mobile berbasis internet
dan server cloud Blynk. Hasil penelitian menunjukkan bahwa pengujian akurasi
sensor pH didapatkan rata-rata error sebesar 1,52%, sensor suhu rata-rata error
sebesar 0,238%, sensor oksigen terlarut rata-rata error sebesar 0,23% dan
amonia rata-rata error sebesar 1,723%.Hasil pengujian ini terlihat bahwa sistem
pemantauan berjalan seperti yang diharapkan.
Abtrak (Bhs. Inggris)Aquaponics is a sustainable agriculture system in a symbiotic environment by
combining aquaculture and hydroponics. This water sistem should flow on the planting medium periodically to ensure the plants get the nutrients, while the water can be filtered properly by the medium. The purpose of this research is to design a water quality monitoring system for an aquaponic system based on the Internet of Things (IoT). The research method is carried out by assembling, developing and integrating several sensors of water quality parameters including pH, temperature, dissolved oxygen, and ammonia. This system integration uses internet-based mobile applications and Blynk cloud servers. Results showed that the accuracy of the pH sensor for acidic water is 1.52% of error, temperature sensor had an average error of 0.238%, dissolved oxygen had an average error of 0,23% and ammonia had an average error of 1.732% and the monitoring sistem proceeded as expected goal.
Kata kunciAquaponics, Water quality, Sensors, Internet of Things.
Pembimbing 1Taufik Budhi Pramono, S.Pi., M.Si
Pembimbing 2Dadang Iskandar, S.T., M.Eng
Pembimbing 3
Tahun2022
Jumlah Halaman9
Tgl. Entri2022-01-28 11:25:24.805706
Cetak Bukti Unggah