Judul ArtikelPENGARUH VARIASI MUTU BETON SERTA PANJANG PENYALURAN SAMBUNGAN
BAJA TULANGAN ULIR LURUS DAN KAIT TERHADAP KUAT LEKAT BETON
Abstrak (Bhs. Indonesia)Kegagalan struktur sering terjadi karena kuat ikatan antara beton dan tulangan yang tidak memadai.
Distribusi tegangan ikatan mempengaruhi lebar retak dan defleksi di sepanjang tulangan dan slip antara
beton dan tulangan. Tujuan dari penelitian ini untuk mengetahui kekuatan lekat antara besi tulangan ulir
dan beton dengan permodelan seperti yang terjadi dilapangan. Benda uji balok akan ditanamkan besi
tulangan ulir kait 180o
dan tanpa kait/lurus dengan panjang penyaluran yang berbeda dan mutu beton
yang digunakan adalah sebesar 20 MPa, 22,5 MPa dan 25 MPa. Pengujian dilakukan dengan cara uji
tarik (pull out) menggunakan alat Universal Testing Machine (UTM). Hasil pengujian didapatkan nilai
deformasi dan beban maksimum. Kemudian data diolah sehingga menghasilkan nilai kuat lekat dan
panjang penyaluran, nilai panjang penyaluran akan dibandingkan dengan nilai panjang penyaluran yang
disyaratkan dalam RSNI 2847:2018. Hasil penelitian menunjukkan kuat lekat dan panjang penyaluran
terbesar terdapat pada benda uji 20K-100 berturut-turut sebesar 5,7945 MPa dan 6462,37 mm. Hal ini
menunjukkan beton bertulang dengan tulangan yang di tekuk/kait dapat menahan gaya tarik lebih besar.
Abtrak (Bhs. Inggris)Structural failures often occur due to inadequate bond strength between concrete and reinforcement.
The distribution of bond stress affects the crack width and deflection along the reinforcement and the
slip between the concrete and the reinforcement. The purpose of this study was to determine the
adhesion strength between screw reinforcing bars and concrete by modeling as occurs in the field.
Beams with dimensions of 40 cm x 10 cm x 18 cm will be implanted with 180hook thread reinforcement
and without hooks / straight with distribution lengths of 100 mm, 200 mm and 300 mm, the quality of the
concrete used is 20 MPa, 22.5 MPa and 25 MPa. Testing is carried out using Universal Testing
Machine (UTM). The test results obtained the maximum deformation and load values. Then the data is
processed so that it produces the value of sticky strength and distribution length, the value of the length
of distribution will be compared with the length of distribution required in RSNI 2847: 2018. The results
showed that the greatest adhesion strength and distribution length were found in the 20K-100 specimen
of 5.7945 MPa and 6462.37 mm, respectively. This shows that reinforced concrete with bent / hook
reinforcement can withstand a greater tensile force.
Kata kunciBeton, Tulangan Ulir Kait, Tulangan Ulir Lurus, Kuat Lekat, Panjang Penyaluran