Artikel Ilmiah : H1A015012 a.n. AMIN FIRDAUS TATANEGARA

Kembali Update Delete

NIMH1A015012
NamamhsAMIN FIRDAUS TATANEGARA
Judul ArtikelSTUDI ANALISIS PENGARUH OVERLAP TIME PADA INVERTER SUMBER ARUS TIGA FASA PWM LIMA TINGKAT
Abstrak (Bhs. Indonesia)Salah satu elemen penting dalam proses konversi energi listrik yaitu inverter, dimana fungsinya yaitu mengkonversi tegangan atau arus searah menjadi tegangan atau arus bolak balik. Salah satu jenis inverter yaitu inverter tiga fasa current source inverter (CSI) lima tingkat yang diusulkan dalam laporan tugas akhir ini. Tujuan dari makalah ini adalah untuk menganalisis pengaruh overlap time agar dapat mencegah atau menghindari keadaan open circuit, overlap time compensation ditambahkan pada sinyal pulsa (gating switch) selama proses pergantian sakelar sehingga dapat terus memberikan suplai arus DC dengan cara mengcross-over sinyal carrier dan merubah nilai DC offset serta peak to peak. Dalam menghasilkan arus keluaran inverter dapat dikendalikan dengan teknik pulse width modulation (PWM). Pembahasan dari makalah ini untuk menganalisis pengaruh overlap time dari 1 µs sampai 6 µs pada inverter tiga fasa lima tingkat dengan menggunakan metode menggunakan 2 sinyal carrier dan 4 sinyal carrier. Parameter yang diamati meliputi kondisi indeks modulasi (im) antar 0≤im≤1 untuk menghasilkan karateristik gelombang arus keluaran, dimana hasilnya dengan semakin kecil nilai indeks modulasi atau mendekati 0 (nol) maka nilai total harmonic distortion (THD) akan semakin besar. Sedangkan untuk indeks moduasi yang mendekati nilai 1, maka nilai THD akan semakin kecil. Kondisi berikutnya yaitu dalam penggunaan compesation (kompensasi) overlap time yang digunakan untuk meminimalisir pengaruh overlap time, karena dalam penggunaannya dapat menyebabkan patahan atau celah pada gelombang keluaran sehingga tidak membentuk sinusoidal murni, dalam hal ini untuk mengurangi keadaan tersebut digunakan nilai kompensasi dengan nilai yang berbeda untuk setiap nilai overlap time yang digunakan, untuk penelitian ini memakai kompensasi antara 0% sampai 30%. Yang terakhir menganalisis perbandingan spektrum harmonisa antara tanpa kompensasi dan dengan kompensasi yang memiliki nilai THD rendah untuk melihat arus keluaran yang dihasilkan.
Abtrak (Bhs. Inggris)One important element in the conversion of electrical energy is an inverter, where the function is to convert voltage or direct current into a voltage or alternating current. One type of inverter is the five-level inverter three-phase inverter source (CSI) approved in this final report by connecting a single phase of five levels with the connection Y (wye) on the load. The purpose of this paper is to analyze the effect of overlapping time in order to prevent or avoid open circuits, overlapping the time of compensation added to the pulse signal (switch gating) during the switch switching process can be used to provide DC current supply by crossing over the carrier signal and trying DC offset value also from peak to peak. In producing inverter output current can be done by pulse width modulation (PWM) technique. With this technique large currents can be arranged. The discussion of this paper is to analyze the effect of overlapping time from 1 μs to 6 µs on a five-level three phase inverter using a method using 2 carrier signals and 4 carrier signals. The parameters discussed using a different modulation index (im) are made between 0≤im≤1 to produce characteristics of the output current wave, while the result with a small increase in the modulation index value or the result of 0 (zero) will increase the total value of harmonic distortion big. While for the modulation index which opens value 1, the THD value will be smaller. Overlapping compensation for use (overlapping) time is used to minimize overlapping time, because its use can cause faults or overlaps in output waves that cause pure sinusoidal, in this case to be used for each time overlapping value used, for this study , use compensation between 0% and 30%. The latter evaluates the harmonious comparison between those without compensation and those with low THD values to see the current produced.
Kata kuncitiga fasa, current source inverter (CSI), PWM, overlap time, lima tingkat.
Pembimbing 1Dr. Eng. Suroso S.T., M.Eng.
Pembimbing 2Eko Murdyantoro AM, S.T., M.T.
Pembimbing 3
Tahun2019
Jumlah Halaman16
Tgl. Entri2019-04-05 13:22:27.201803
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.