Judul ArtikelANALISIS PROTEKSI TEGANGAN INDUKSI SURJA PETIR PADA SALURAN UDARA TEGANGAN MENENGAH (SUTM) 20 kV STUDI KASUS TRAFO I PT. PLN (PERSERO) UNIT PELAYANAN JARINGAN PURBALINGGA
Abstrak (Bhs. Indonesia)Lightning arrester merupakan alat proteksi bagi peralatan listrik terhadap tegangan lebih, yang disebabkan oleh petir atau surja hubung (switching surge). Alat ini bersifat sebagai by-pass di sekitar isolasi yang membentuk jalan dan mudah dilalui oleh arus kilat ke sistem pentanahan sehingga tidak menimbulkan tegangan lebih yang tinggi dan tidak merusak isolasi peralatan listrik. Pada penelitian ini, digunakan dua jenis arrester yaitu Metal-Oxide Arrester (MOA) dan Multi-Chamber Arrester (MCA). Pada prinsipnya kedua arrester ini sama dalam kegunaannya, hanya saja berbeda dalam prinsip kerjanya. Pada Metal-Oxide Arrester surja petir yang diterima akan disalurkan ke tanah, sedangkan pada Multi-Chamber Arrester surja petir yang diterima akan langsung dibuang ke udara. Oleh karena itu, perbedaan dua jenis arrester pada penelitian ini bertujuan untuk meminimalisir gangguan yang disebabkan oleh surja petir. Penelitian ini akan melakukan analisa, penanggulangan dan sistem pengaman terhadap gangguan petir pada trafo I. Gangguan ini tidak boleh terabaikan karena akan mengakibatkan tegangan induksi petir yang akan merusak peralatan listrik. Dalam studi kasus trafo I, akan dianalisa kinerja arrester dalam menanggulangi sambaran induksi petir yang terjadi pada saluran distribusi 20 kV. Berdasarkan perhitungan spesifikai arrester yang terpasang yaitu MOA memiliki rating tegangan 17,6 kV dan dan MCA 22 kV sehingga dengan spesifikasi arrester tersebut dapat mengatasi gangguan sambaran induksi petir. Simulasi menggunakan program ATP dengan memodelkan penyulang PBG 03, PBG 04, dan PBG 05 dan menganalisa sambaran pada titik yang sering mengalami gangguan. Penggantian arrester yang sudah tidak layak ataupun penambahan arrester pada section yang tidak terpasang arrester pada penyulang dapat menurunkan tegangan sehingga tidak melebihi nilai tegangan maksimum sebesar 11,547 kV.
Abtrak (Bhs. Inggris)Lightning arresters are protection devices for electrical equipment against overvoltages, which are caused by lightning or switching surges. This tool is as a by-pass in the vicinity of the insulation that forms the road and is easily traversed by flash currents to the grounding system so that it does not cause high overvoltages and does not damage the insulation of electrical equipment. In this study, two types of arresters were used, namely Metal-Oxide Arrester (MOA) and Multi-Chamber Arrester (MCA). In principle, the two arresters are the same in their use, only different in their working principle. In the Metal-Oxide Arrester received lightning surge will be channeled to the ground, while in the Surge Lightning Multi-Chamber Arrester received will be immediately discharged into the air. Therefore, the difference in the two types of arresters in this study aims to minimize the interference caused by lightning surges. This study will conduct analysis, countermeasures and safety systems against lightning disturbances on transformer I. This interference should not be overlooked because it will cause lightning induction voltage which will damage electrical equipment. In the transformer case study I, the performance of arresters will be analyzed in overcoming lightning induction strikes that occur on the 20 kV distribution channel. Based on the calculation of installed arrester specifications, the MOA has a voltage rating of 17.6 kV and a MCA of 22 kV so that with the specifications of the arrester it can overcome lightning induction stroke interference. Simulation uses the ATP program by modeling PBG 03, PBG 04, and PBG 05 feeders and analyzing strikes at points that often experience interference. Replacement of arresters that are not feasible or the addition of arresters in sections that are not installed arresters in feeders can reduce the voltage so that it does not exceed the maximum voltage value of 11,547 kV.
Kata kunciLightning Arrester, Metal-Oxide Arrester, Multi-Chamber Arrester, ATPDraw, Proteksi Petir
Pembimbing 1Hari Prasetijo,S.T.,M.T
Pembimbing 2Hesti Susilawati,S.T.,M.T
Pembimbing 3
Tahun2019
Jumlah Halaman13
Tgl. Entri2019-02-20 01:41:51.123473
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.