| NIM | H1A014033 |
| Namamhs | AHMAD HADI ISMOYO |
| Judul Artikel | Pengembangan Biosensor Glukosa Menggunakan Beads Alginat dan Detektor TCS230 |
| Abstrak (Bhs. Indonesia) | Pengembangan biosensor glukosa merupakan salah satu strategi penting pada deteksi dini penyakit diabetes mellitus. Penelitian ini bertujuan untuk mengetahui potensi analisis kadar glukosa menggunakan sensor TCS230. Analisis kadar glukosa dilakukan dengan mereaksikan glukosa dengan enzim glukosa oksidase yang telah diambolisasi dengan matriks alginat menghasilkan H2O2. Hidrogen peroksida yang terbentuk direaksikan dengan indikator TiOSO4 yang menghasilkan warna kuning dan intensitas warnanya diukur menggunakan sensor warna TCS230. Pengembangan biosensor glukosa ini dilakukan beberapa validasi seperti waktu optimasi, linearitas, LOD, LOQ, keberulangan, akurasi, dan selektivitas. Hasil penelitian menunjukkan sensor warna TCS230 memberikan respon linear dengan % glukosa. Respon linear yang didapat pada rentang konsentrasi 0,5–10 mM dengan R2 sebesar 0,9904. Uji kinerja biosensor glukosa menunjukkan waktu optimum reaksi enzimatis pada menit ke-10. Batas deteksi (LOD) sebesar 1,208 mM dan batas kuantifikasi (LOQ) sebesar 4,025 mM. Keberulangan biosensor dapat digunakan berulang hingga 10 kali. Biosensor glukosa ini memiliki respon akurasi sebesar 100% dan memiliki selektivitas terhadap penambahan asam urat dengan konsentrasi 0,03 mM. Analisis kadar glukosa dalam sampel darah pada penelitian ini menunjukkan hasil yang tidak berbeda nyata dengan analisis glukosa yang diperoleh dengan metode Somogy-Nellson.
|
| Abtrak (Bhs. Inggris) | Development of glucose biosensor is one of the important strategies in early detection of diabetes mellitus disease. This study aims to determine the potential of glucose analysis using a TCS230 sensor. Glucose level analysis was performed by reacting glucose with glucose oxidase enzyme that has been immobilized with alginate matrix producing H2O2. The hydrogen peroxide formed is reacted with the indicator TiOSO4 which produces a yellow color and the color intensity is measured using a TCS230 color sensor. Development of glucose biosensors is done some validation such as optimization time, linearity, LOD, LOQ, repeatability, accuracy, and selectivity. The results showed that the TCS230 color sensor provides a linear response with% glucose. The linear response obtained in the concentration range of 0,5-10 mM with R2 is 0,9904. Glucose biosensor performance test showed the optimum time of enzymatic reaction at minute 10. The detection limit (LOD) is 1,208 mM and the quantification limit (LOQ) is 4,025 mM. Biosensor repeatability can be used repeatedly up to 10 times. This glucose biosensor has an accuracy response of 100% and has a selectivity to the addition of uric acid with a concentration of 0,03 mM. Analysis of glucose levels in blood samples in this study showed results that were not significantly different from the glucose analysis obtained by the Somogy-Nellson method.
|
| Kata kunci | biosensor, TCS230, amobilisasi, glukosa oksidase, validasi. |
| Pembimbing 1 | Amin Fatoni, Ph.D |
| Pembimbing 2 | Zusfahair, S.Si., M.Si |
| Pembimbing 3 | |
| Tahun | 2018 |
| Jumlah Halaman | 77 |
| Tgl. Entri | 2018-07-11 09:25:43.446798 |
|---|