| Judul Artikel | PENGEMBANGAN BIOSENSOR GLUKOSA MENGGUNAKAN BEADS ALGINAT DAN DETEKTOR LDR (LIGHT DEPENDENT RESISTOR) |
| Abstrak (Bhs. Indonesia) | Pengembangan biosensor glukosa merupakan salah satu strategi penting pada deteksi dini penyakit diabetes mellitus. Penelitian ini bertujuan untuk mengetahui analisis glukosa dengan menggunakan sensor warna dengan komponen light dependent resistor (LDR) menggunakan metode kolorimetri. LDR merupakan suatu sensor warna yang dapat membaca intensitas warna dari suatu sampel. Sensor LDR dalam penelitian ini digunakan untuk membaca intensitas warna yang dihasilkan oleh reaksi enzimatis antara beads alginat-glukosa oksidase dan glukosa dengan penambahan indikator Titanium (IV) oksisulfat (TiOSO4) yang menghasilkan warna kuning. Pengembangan biosensor glukosa ini dilakukan beberapa validasi yang meliputi akurasi, linearitas, batas deteksi dan batas kuantifikasi, rentang metode, selektivitas, keberulangan pembuatan, dan keberulangan analisis. Uji validasi pada penelitian ini menunjukkan waktu optimum reaksi enzimtis pada menit ke-15. Respon linear yang didapat pada rentang konsentrasi 0,5 – 10 mM dengan koefisien korelasi 0,9901. Batas deteksi (LOD) sebesar 1,14 mM dan batas kuantifikasi sebesar 3,81 mM. Stabilitas biosensor dapat digunakan berulang hingga 8 kali. Analisis glukosa dalam sampel darah pada penelitian ini menunjukan hasil yang tidak berbeda nyata dengan analisis glukosa yang diperoleh dengan metode Somogyi Nelson.
|
| Abtrak (Bhs. Inggris) | Development of glucose biosensor is one of the important strategies in the early detection of diabetes mellitus disease. This study aims to determine the analysis of glucose by using a color sensor with light dependent resistor components (LDR) with a colorimetric method. LDR is a color sensor that can read the color intensity of a sample. The LDR sensor in this study was used to read the color intensity produced by enzymatic reactions between alginate-glucose oxidase and glucose beads with the addition of Titanium (IV) oxysulfate (TiOSO4) indicator which produced a yellow color. Development of glucose biosensors is done some validation that includes accuracy, linearity, detection limit and quantification limit, the range of methods, selectivity, repeatability of manufacture, and repeatability analysis. Validation test in this study showed the optimum time of enzyme reaction at minute 15. The linear response obtained in the concentration range 0.5 - 10 mM with a correlation coefficient of 0.9901. The detection limit (LOD) of 1.14 mM and the quantification limit of 3.81 mM. Biosensor stability can be used repeatedly up to 8 times. Glucose analysis in blood samples in this study showed results that did not differ significantly with glucose analysis obtained by the method Somogyi Nelson.
|
| Kata kunci | Keywords: biosensor, LDR, alginate beads, glucose oxidase, validation |
| Pembimbing 1 | Amin Fatoni, S.Si, M.Si, Ph.D |
| Pembimbing 2 | Zusfahair, M.Si |
| Pembimbing 3 | |
| Tahun | 2018 |
| Jumlah Halaman | 76 |
| Tgl. Entri | 2018-07-10 17:36:03.72492 |
|---|