| Judul Artikel | PENGEMBANGAN BIOSENSOR UREA MENGGUNAKAN UREASE AMOBIL PADA MATRIKS KALSIUM ALGINAT DAN DETEKTOR LDR (LIGHT DEPENDENT RESISTOR) |
| Abstrak (Bhs. Indonesia) | Keberadaan urea di dalam tubuh menjadi parameter biologi yang penting untuk identifikasi penyakit ginjal. Penyakit ginjal ditandai dengan kadar urea dalam serum yang melebihi kadar normal. Pengembangan metode pengukuran urea akhir-akhir terus dikembangkan salah satunya menggunakan biosensor. Telah dilakukan pengembangan biosensor urea menggunakan urease amobil pada matriks alginat dan detektor LDR. Urease diamobilisasi dengan teknik penjebakkan dalam matriks kalsium alginat kemudian direaksikan dengan larutan urea. Hasil reaksi ditambah dengan indikator warna BTB kemudian diukur menggunakan detektor LDR secara kolorimetri dan dikuantisasi dalam program Color Sensor Reader. Hasil yang didapatkan dari penelitian ini berupa waktu optimum reaksi selama 4 menit, linearitas yang baik dengan nilai koefisien relasi (r) sebesar 0,9979 dan memberikan sensitivitas tertinggi pada intensitas warna merah dengan nilai KV 4,368%; HORRAT 0,815; batas deteksi sebesar 0,3535 mM; batas kuantifikasi sebesar 1,1784 mM; rentang metode sebesar 1,1784 mM hingga 42,6531 mM; stabilitas pemakaian berulang urease amobil sebanyak 11 kali pemakaian (kestabilan >50%), dan kurang selektif dengan adanya asam askorbat maupun asam urat. Kadar urea dalam 6 sampel serum darah yang dianalisis menunjukkan tidak terdapat perbedaan yang bermakna antara hasil analisis klinik dengan hasil analisis biosensor menggunakan detektor LDR dengan nilai rata-rata konstanta hasil pengukuran biosesnsor sebesar 1,264. |
| Abtrak (Bhs. Inggris) | The existence of urea in the body becomes an important biological parameter for the identification of kidney disease. Kidney disease is characterized by serum urea levels that exceed normal levels. Development of urea measurement methods recently developed one of them using biosensor. A urea biosensor has been developed using immobilized urease in alginate matrix and LDR detector. Urease is immobilized by tracer technique in calcium alginate matrix then reacted with urea solution. The reaction product plus the BTB color indicator is then measured using a LDR detector colorimetrically and quantized in the Color Sensor Reader program. The result of this research is optimum reaction time for 4 minutes, good linearity with relation coefficient value (r) equal to 0.9979 and give highest sensitivity at red color intensity with value of KV 4.368%; HORRAT 0.815; detection limit of 0.3535 mM; quantification limit of 1.1784 mM; the method range of 1.1784 mM to 42.6531 mM; stability of repeated use of immobilized urease 11 times (stability> 50%), and less selective in the presence of ascorbic acid and uric acid. Levels of urea in 6 blood serum samples analyzed showed no significant differences between the results of clinical analysis with the results of biosensor analysis using LDR detector with the average value of the constant biosesnsor measurement results of 1.264. |
| Kata kunci | biosensor, urea, urease, amobil, kalsium alginat, LDR, kolorimetri |
| Pembimbing 1 | Zusfahair, S.Si., M.Si. |
| Pembimbing 2 | Amin Fatoni, Ph.D. |
| Pembimbing 3 | - |
| Tahun | 2018 |
| Jumlah Halaman | 88 |
| Tgl. Entri | 2018-07-10 13:52:10.940994 |
|---|