| Judul Artikel | PENGEMBANGAN FLOW INJECTION BIOSENSOR DENGAN AMOBILISASI Escherichia coli SEBAGAI BIORESEPTOR UNTUK DETEKSI TOKSIKAN TIMBAL(Pb) DALAM PERAIRAN |
| Abstrak (Bhs. Indonesia) | Pengembangan biosensor menggunakan E.coli yang diamobilisasi sebagai bioreseptor untuk mendeteksi keberadaan Pb dalam air dengan system diam kurang efektif karena membutuhkan waktu preparasi yang lama. Penelitian ini diawali dengan pembuatan beads yang selanjutnya ditaruh dalam rangkaian FIA sebagai detektor. Kemudian dilakukan serangkaian optimasi meliputi panjang gelombang pengukuran, waktu tampung, jumlah beads, volume injeksi, dan laju alir. Beads juga dilakukan uji respon deteksi Pb, uji akurasi, uji keberulangan pemakaian beads, serta pengujian pada sampel air. Hasil penelitian menunujukkan bahwa nilai AbsT/AbsI ini berkorelasi dengan konsentrasi toksikan (R2=0,922). Metode ini presisi dan akurat dengan nilai RSD 8,3% dan recovery 92%. Didapatkan nilai LOD dan LOQ sebesar 89 mg/L dan 297 mg/L. Beads masih dapat mempertahankan kemampuannya hingga pemakaian ke-3. Biosensor dengan E.coli amobil dengan teknik flow injection analysis dapat mendeteksi toksikan Pb di perairan dengan parameter kinerja linearitas baik, RSD 8,3%, recovery 92%, LOD 89 mg/L, dan LOQ 297 mg/L |
| Abtrak (Bhs. Inggris) | The development of biosensor using immobilized E.coli for detection lead in water not too effective because of need long time for preparation. Flow Injection Analysis (FIA) used for analyze with quickest time and no need long time for preparation. This study started by beads formed and then placed in FIA system as detector. The analytical performance studies including the optimization of: maximum wavelength, amount of beads, time to accommodate, injection volume, and flow rate. The sensitivity of beads to Pb was tested, accuracy, stability of repeated used was tested as well.The result show that AbsT/AbsI value have correlation with the toxicity concentration. FIA system showed accuracy and precision with RSD 8,3% and recovery 92%. LOD and LOQ for FIA calculated to be 89 mg/L and 297 mg/L. Beads could be defend its ability until third usage. Biosensor using immobilized E.coli can detect Pb in water with analytical performance good linearity, RSD 8,3%, recovery 92 %, LOD 89 ppm, dan LOQ 297 ppm. |
| Kata kunci | Biosensor, Prussian blue, flow injection analysis, Escherichia coli, timbal. |
| Pembimbing 1 | Hendri Wasito, M.Sc, Apt |
| Pembimbing 2 | Amin Fatoni, Ph.D |
| Pembimbing 3 | |
| Tahun | 2018 |
| Jumlah Halaman | 10 |
| Tgl. Entri | 2018-05-25 11:31:42.087603 |
|---|