Judul ArtikelANALISIS ARUS TRANSIENT AKIBAT PENGARUH BEBAN MENGGUNAKAN SOFTWARE Atpdraw/EMTP STUDI KASUS TRANSFORMATOR 5 DI GARDU INDUK KALIBAKAL PT PLN (PERSERO) UTJBT APP PURWOKERTO
Abstrak (Bhs. Indonesia)Transformator 5 GI Kalibakal baru beroperasi pada awal tahun 2017. Tujuan dari penelitian ini untuk mengetahui pemodelan menggunakan software Atpdraw, karakteristik dan gejala arus transient, serta prediksi suhu akibat pengaruh beban. Pemodelan menggunakan software Atpdraw dilakukan dengan mengikuti single line diagram Transformator 5 GI Kalibakal. Sumber tegangan sebesar 150kV. Terdapat beberapa komponen dalam simulasi yang saling berhubungan satu sama lain. Besar beban yang digunakan dalam simulasi untuk mengetahui besar arus transient dan suhu transformator adalah 35%, 45%, 55%, 65%, 75%, 85%, 95% dan 100%. Arus transient yang terjadi dibagi kedalam 3 keterangan yaitu aman, rawan, dan berbahaya. Ketika beban transformator sebesar 35% arus transient per fasa RST yaitu 3896 A, 3900 A, dan -3710 A masuk kedalam keterangan aman, ketika beban 65% arus transient per fasa RST yaitu 5732 A, 5734 A , dan -5583 A masuk kedalam keterangan rawan, ketika beban 85% arus transient per fasa RST yaitu 7039 A, 7072 A, dan -6350 A masuk kedalam keterangan berbahaya. Sedangkan suhu dibagi menjadi 2 keterangan yaitu aman dan berbahaya. Ketika beban sebesar 35% suhu transformator 34,3o C masuk keterangan aman, sedangkan ketika beban 85% suhu transformator 83,3o C keterangan berbahaya. Jadi, semakin besar beban maka semakin besar pula arus transient dan suhu yang terjadi begitu pula sebaliknya. Jika arus transient dan suhu yang terjadi melebihi batas aman berpotensi merusak komponen dalam transformator sehingga dapat berpengaruh terhadap kinerja transformator.
Abtrak (Bhs. Inggris)Kalibakal 5 GI Transformer operates in early 2017. The purposes of this research is to know the modeling using Atpdraw software, the characteristics and symptoms of transient currents, and the prediction of temperature due to load effect. Modeling using Atpdraw software is done by following the single line diagram of Transformer 5 GI Kalibakal. The source voltage is 150kV. There are several components in the simulation that are interconnected each other. The amount of load used in the simulation to know the transient current and transformer temperature are 35%, 45%, 55%, 65%, 75%, 85%, 95% and 100%. The transient currents that occur are divided into 3 information that is safe, vulnerable, and dangerous. When the transformer load of 35% of the transient current per RST phase ie 3896 A, 3900 A, and -3710 A goes into the secure description, when the load 65% of the transient current per RST phase is 5732 A, 5734 A, and -5583 A entered into the description prone, when the 85% load of transient currents per RST phase of 7039 A, 7072 A, and -6350 A goes into malicious information. While the temperature is divided into 2 information that is safe and dangerous. When the load of 35% transformer temperature 34.3o C enter the safe description, while when the 85% load temperature of the transformer 83.3o C of the information is dangerous. In the conclusion, more greater expense make an effect more greater the transient current and the temperature occurring and vice versa. If transient currents and temperatures that occur over the safe limit potentially damage the components in the transformer so as to affect the performance of the transformer.
Kata kunciTransformator, Beban, Atpdraw/EMTP
Pembimbing 1Daru Tri Nugroho,ST.,MT
Pembimbing 2Hari Prasetijo,ST.,MT
Pembimbing 3
Tahun2017
Jumlah Halaman18
Tgl. Entri2017-11-08 20:53:11.299551
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.