Artikel Ilmiah : H1C013047 a.n. GESIT TRIYANDI SAPUTRO

Kembali Update Delete

NIMH1C013047
NamamhsGESIT TRIYANDI SAPUTRO
Judul ArtikelANALISIS PENGARUH UPRATING TERHADAP PROTEKSI RELAY JARAK SEBAGAI PENGAMAN UTAMA SALURAN TRANSMISI 150 KV STUDI KASUS GI KARET PT.PLN(PERSERO) APP PULOGADUNG
Abstrak (Bhs. Indonesia)Gardu Induk Karet APP Pulogadung merencanakan proyek penambahan 1 trafo berkapasitas 60 MVA. Penambahan kapasitas ini dilakukan karena beban yang mendekati beban maksimum GI Karet. Saat ini GI Karet memiliki 3 trafo dengan kapasitas masing – masing 60 MVA. Pada penelitian ini bertujuan untuk menganalisa pengaruh penambahan 1 trafo dan menganalisa kehandalan proteksi relay jarak pada saluran transmisi 150kV GI Karet arah GI Angke. Penelitian ini dilakukan dengan metode studi pustaka dan perancangan simulasi untuk gangguan arus hubung singkat dengan software ETAP 12.6.0. Hasil yang diperoleh pada perhitungan nilai setting relay jarak masing – masing zone sebesar: zone 1 = 3.16 Ω, zone 2 = 4.4 Ω, dan zone 3 = 7.02 Ω. Tidak terlalu terjadi perubahan yang signifikan pada nilai setting relay jarak, sehingga kehandalan proteksi relay jarak pada saluran transmisi 150kV di GI Karet masih termasuk dalam kategori baik.
Abtrak (Bhs. Inggris)GI Karet APP Pulogadung has plans to addition 1 transformer with 60 MVA capacity. This addition capacity is because the load of GI Karet is close to maximum. Now GI Karet has 3 transformers, each transformer has 60 MVA capacity. This research has the purpose to analyze influence of addition 1 transformer and analyze the reliability of distance relay protection on 150kV transmission line from GI Karet to GI Angke. This research use literature study method and designing simulation for interference of short circuit with ETAP 12.6.0. The result obtained on the calculating of distance relay setting value each zone has zone 1 = 3.16 Ω, zone 2 = 4.4 Ω, and zone 3 = 7.02 Ω. From this result can be infer that there is no significant change on setting value of distance relay, so reability of distance relay protection on 150 kV transmission line on GI Karet include in a good category.
Kata kunciUprating, Saluran Transmisi, Relay Jarak, ETAP
Pembimbing 1Daru Tri Nugroho, S.T.,M.T.
Pembimbing 2Winasis, S.T.,M.Eng.
Pembimbing 3
Tahun2017
Jumlah Halaman87