Judul ArtikelANALISA UNJUK KERJA TRAFO PADA SISTEM KONEKSI PLTS LOW VOLTAGE HIGH CURRENT DENGAN POWER GRID MENGGUNAKAN H-BRIDGE CURRENT SOURCE INVERTER
Abstrak (Bhs. Indonesia)Kualitas energi listrik yang dihasilkan sistem Photovlotaic (PV) bergantung pada beberapa hal, diantaranya intensitas energi surya, posisi sudut datangnya sinar matahari, kehandalan PV inverter, rugi-rugi pada komponen listrik dan lain sebagainya. Guna mengetahui kualitas keluaran energi listrik yang dihasilkan, maka perlu dilakukan analisis unjuk kerja pada setiap komponen terpasang pada topologi sistem PLTS. Dengan melakukan analisis unjuk kerja pada transformator diharapkan dapat memberikan informasi terkait kualitas kinerja transformator. Analisa unjuk kerja trafo pada sistem koneksi PLTS Low Voltage High Current dengan Power Grid menggunakan H-Bridge CSI yaitu dengan melakukan pengujian untuk mengetahui karakteristik nilai arus primer dan sekunder trafo, arus beban dan arus dari grid 220V, dimana nilai THD ditentukan oleh nilai indeks modulasi dan referensi nilai arus DC pada kendali buck converter. Simulasi untuk nilai arus dilakukan ketika nilai amplitudo arus referensi DC diubah-ubah dengan rentang nilai 25 A, 50 A, 75 A, 100 A, 125 A, 150 A, 175A dan 200 A, untuk indeks modulasi diset tetap pada nilai 0,9. Nilai THD arus primer trafo yang terbesar dihasilkan pada saat pengujian nilai arus DC referensi 75 A dengan nilai THD sebesar 0.25982868% dan nilai THD arus sekunder trafo yang terbesar dihasilkan pada saat pengujian nilai arus DC referensi bernilai 75 A dengan nilai THD sebesar 0.26020046%. Nilai efisiensi trafo tertinggi yakni pada saat nilai arus DC referensi diatas 100 A (100-200 A) dengan nilai efisiensi sebesar 96.4979826%.
Abtrak (Bhs. Inggris)The quality of electrical energy generated by the Photovlotaic (PV) system depends on several things, such as the intensity of solar energy, the angular position of the sun, the reliability of PV inverters, losses in electrical equipments and etc. In order to know the quality of the electrical energy generated output, it is necessary to analyze the performance of each component installed on the topology of PV system. By analyzing the transformer performance is expected to provide information regarding the quality of the transformer performance. Performance analysis of transformer in connection system of PLTS LVHC with power grid using H-Bridge CSI with a test to know the characteristics of the primary current and secondary current, load current and the current from the 220V grid, where the value of THD is determined by the value of the modulation index and DC reference current in buck converter control. Simulation of current value to do when amplitude of DC reference current changed by the range of 25 A, 50 A, 75 A, 100 A, 125 A, 150 A, 175A and 200 A, for fixed modulation index is set at 0,9. The highest THD primary current produced at the time of testing DC reference current value at 75 A with 0.25982868%, and the highest THD secondary current which generated at the time of testing DC reference current value at 75 A with 0.26020046% THD. The highest transformer efficiency is during DC reference current at above 100 A (100-200 A) with 96.4979826%.
Kata kunciPhotovoltaic, Transformator, H-Bridge CSI
Pembimbing 1Dr. Eng. Suroso, S.T., M.Eng.
Pembimbing 2Daru Tri Nugroho, S.T., M.T.
Pembimbing 3
Tahun2016
Jumlah Halaman12
Tgl. Entri2016-08-12 10:54:43.040489
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.