| NIM | H1C012023 |
| Namamhs | EDGINA JAGAR HANDHANU |
| Judul Artikel | ANALISIS PENGAMAN DAN GANGGUAN SURJA PETIR UNTUK KEHANDALAN SALURAN UDARA TEGANGAN MENENGAH (SUTM) 20 kV STUDI KASUS PENYULANG KBL. 02 DI PT. PLN (Persero) AREA PELAYANAN JARINGAN PURWOKERTO |
| Abstrak (Bhs. Indonesia) | Gangguan yang besar dalam sistem tenaga listrik terjadi di daerah penyaluran (transmisi dan distribusi). Diantara sekian banyak gangguan yang terjadi, petir merupakan salah satu penyebabnya. Letak Indonesia pada daerah khatulistiwa dengan iklim tropis dan kelembaban yang tinggi, sehingga menyebabkan kerapatan sambaran petir di Indonesia tinggi. Salah satu aset jaringan PT. PLN (PERSERO) APJ PURWOKERTO yang sering mengalami gangguan petir adalah penyulang KBL. 02 terutama di zone 2. Permasalahan diatas perlu dikaji sehingga kita dapat menentukan sistem proteksi terhadap gangguan petir pada penyulang KBL. 02 zone 2 secara efektif agar sistem proteksi dan kehandalan pelayanan menjadi lebih baik, dan dapat menyelesaikan permasalahan tersebut secara ekonomis dan efisien. Berdasarkan dari hasil perhitungan arrester, untuk arrester yang digunakan di lapangan yaitu dengan spesifikasi rating tegangan 18 kV dan arus 5 kA dengan tegangan pelepasan 150 kV, diharapkan arrester bisa meminimalisir gangguan sambaran induksi. Hasil yang diperoleh setelah melakukan simulasi menggunakan ATP Draw, arrester dapat mereduksi tegangan yang cukup besar dengan cepat dengan jarak 200 m dari gangguan dan durasi waktu 1,2-5 ms. Dari simulasi juga diperoleh dengan pemasangan arrester semakin dekat dengan peralatan maka akan semakin baik karena waktu pengaman terhadap tegangan lebih surja petir akan semakin cepat. |
| Abtrak (Bhs. Inggris) | The big problem of electrical system happened in the distribution territory (transmision & distribution). Among the many disorders that occur, strom is the one of the causes of the problem. Indonesia is on the equator line with the tropical wheather and the high humidity it causes of the high strike density of the strom in Indonesia high. One of the networking aset of PT. PLN (Persero) which is offenly had the storm problem is feeder KBL. 02 especially in the zone 2. The problems above need to be disscussed so we can decide the protection system towards the lightning disturbances of feeder KBL. 02 zone 2 effectivelly so the protection system an the good reliability will be better, and they can solve those problems economically and efficient. Based on the measurement result of the arrester, for the arrester that used in the field which have 18 kV voltage rating and current 5 kA with voltage discharge 150 kV spesification, hopefully the arrester can minimize the induction stroke interruption. The result after we have done the simulation using ATP Draw, arrester can reduce the high voltage quickly with the distance is about 200 m from the problem and with the duration is about 1,2-5 ms. From the simulation we also can get when the arrester is closer with to tools so it will be better because the time of safety towards more voltage of the lightning strike will be faster. |
| Kata kunci | Petir, Penyulang KBL. 02, Arrester, ATP Draw |
| Pembimbing 1 | Daru Tri Nugroho., ST., M.T. |
| Pembimbing 2 | Eko Murdyantoro., ST., M.T. |
| Pembimbing 3 | |
| Tahun | 2016 |
| Jumlah Halaman | 87 |
| Tgl. Entri | 2016-08-04 03:55:30.206134 |
|---|