| Judul Artikel | Studi Analisis Arus Bocor Pada PV Terhubung Jala – Jala Listrik Satu Fasa Menggunakan Full-Bridge Inverter Dengan PI Current Controller Tanpa Trafo |
| Abstrak (Bhs. Indonesia) | Salah satu topologi PV adalah grid-connected PV dimana PV terhubung dengan jala-jala listrik PLN. Keluaran DC dari PV dikonversi menggunakan inverter. Inverter tanpa trafo mulai banyak dikembangkan. Topologi ini membuat ukuran, harga dan kompleksitas inverter menjadi berkurang serta memiliki efisiensi yang tinggi. Akan tetapi, hal tersebut akan menaikkan arus bocor pada sisi PV yang dapat menurunkan kinerja maksimum sistem. Hal tersebut dapat diminimalisir dengan topologi dan kontrol pensaklaran yang tepat dari inverter. Pada penelitian ini telah dilakukan analisa arus bocor menggunakan software PSIM terhadap PV yang terhubung jala – jala listrik satu fasa menggunakan full-bridge inverter tanpa trafo dengan PI current controller yang berguna untuk mengatur arus keluaran inverter. Analisa arus bocor dilakukan dengan mengubah nilai rms arus inverter dari 3 A hingga 27 A dengan selisih 3. Dari hasil simulasi diperoleh data bahwa kenaikan arus inverter akan menaikkan ripple tegangan keluaran PV dan penurunan nilai rms nya, perubahan ini mempengaruhi nilai dari arus bocor yang dihasilkan dimana nilai max nya semakin besar dan rms nya turun. Efisiensi sistem paling tinggi didapat saat nilai rms arus inverter 11,992 A. Dalam menaikkan arus inverter tidak boleh melebihi series fuse rating dari rangkaian PV yaitu 30 A. |
| Abtrak (Bhs. Inggris) | One of the PV topology is grid-connected PV where the PV is connected to the grid. The DC output of the PV is converted using an inverter. Inverter without transformer is being developed. This topology makes the size, price and complexity of the inverter are reduced and it has a high efficiency. However, this will increase the leakage current on PV that can reduces maximum system performance. This can be minimized by switching topology and precise control of the inverter. This study has been carried out the analysis of leakage current using PSIM software to the single phase grid-connected PV using a full-bridge inverter without transformer with PI current controller that allows you to adjust the output current inverter. Leakage current analysis is done by changing the rms value of the inverter current of 3 A to 27 A with a difference of 3. From the simulation results data showed that the increase of inverter current will increase the PV output voltage ripple and decrease its rms value, these changes affect the generated value of leakage current which is the max value will increase and the rms value will decrease. Highest system efficiency is obtained when the rms value of the inverter current is 11,992 A. In raising the inverter current may not exceed the rating of series fuse of PV array is 30 A. |
| Kata kunci | PV, Inverter, Arus bocor, PI Current Controller, Arus Inverter |
| Pembimbing 1 | Dr. Eng Suroso, S.T., M.Eng |
| Pembimbing 2 | Winasis, S.T., M.Eng |
| Pembimbing 3 | |
| Tahun | 2016 |
| Jumlah Halaman | 15 |
| Tgl. Entri | 2016-04-20 09:52:05.657576 |
|---|