Artikel Ilmiah : H1E008011 a.n. Isdandy Rezki Febrianto

Kembali Update Delete

NIMH1E008011
NamamhsIsdandy Rezki Febrianto
Judul ArtikelPERANCANGAN KOLIMATOR NEUTRON UNTUK BNCT DENGAN SUMBER 7Li(p 30 MeV,n)7Be MENGGUNAKAN SOFTWARE MCNPX
Abstrak (Bhs. Indonesia)Telah dilakukan penelitian tentang perancangan kolimator neutron untuk fasilitas Boron Neutron Capture Therapy (BNCT) dengan sumber neutron yang berbasiskan reaksi 7Li(p,n)7Be menggunakan perangkat lunak Monte Carlo N-Particle X (MCNPX). Berkas proton yang digunakan pada reaksi tersebut memiliki arus 1,1 mA dan bersifat monodirectional serta monoenergetic dengan energi 30 MeV. Spesifikasi dimensi dari setiap komponen kolimator divariasikan untuk mendapatkan desain yang dapat menghasilkan berkas neutron yang optimal mengacu pada kriteria International Atomic Energy Agency (IAEA). Simulasi menunjukkan bahwa spesifikasi dimensi kolimator neutron yang optimal adalah target 7Li dengan panjang 2,5 cm dan jari-jari 1,5 cm, dinding target dengan material timbal sepanjang 30 cm, moderator air berat dengan panjang 20 cm dan jari-jari 30 cm, moderator aluminium sepanjang 21 cm, reflektor timbal dengan ketebalan 12 cm, filter neutron termal berupa cadmium dengan ketebalan 0,003 cm, aperture dengan celah berjari-jari 6 cm dan panjang total 9,5 cm yang terdiri dari material cadmium sepanjang 0,6 cm dan timbal sepanjang 8,9 cm. Berkas neutron yang dihasilkan memiliki fluks neutron epitermal 4,08×〖10〗^9 neutron 〖cm〗^(-2) s^(-1), dosis neutron cepat tiap fluks neutron epitermal 16,9×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1), dosis gamma tiap fluks neutron epitermal 12×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1), rasio fluks neutron termal terhadap fluks neutron epitermal 0, rasio arus neutron epitermal terhadap total fluks neutron epitermal 0,73. Parameter dosis neutron cepat tiap fluks neutron epitermal dan dosis gamma tiap fluks neutron epitermal belum memenuhi kriteria IAEA yaitu kurang dari 1×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1). Namun untuk parameter dosis gamma tiap fluks neutron epitermal masih berada di dalam batas toleransi IAEA yaitu kurang dari 13×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1).
Abtrak (Bhs. Inggris)A research of neutron collimator design using Monte Carlo N-Particle X (MCNPX) software for the Boron Neutron Capture Therapy (BNCT) facility with a neutron source based on 7Li(p, n)7Be reaction has been conducted. Proton beam that is used in the reaction has a current of 1.1 mA and has properties which are monodirectional and monoenergetic with energy of 30 MeV. Dimensional specifications of each collimator’s component are varied to obtain a design that can produce optimal neutron beam refers to the criteria of the International Atomic Energy Agency (IAEA). Simulations show that the optimal dimensional specifications of neutron collimator are 7Li targets with a length of 2.5 cm and 1.5 cm radius, the target wall based on lead material with 30 cm length, heavy water moderator with a length of 20 cm and 30 cm radius, 21 cm length of aluminum moderators, reflectors based on lead material with a thickness of 12 cm, a thermal neutron filter in the form of cadmium with a thickness of 0.003 cm, slit aperture with a radius of 6 cm and a total length of 9.5 cm which consists of 0.6 cm cadmium material and 8.9 cm lead material. The resulting neutron beam has 4,08×〖10〗^9 neutron 〖cm〗^(-2) s^(-1) epithermal neutron flux, 16,9×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1) fast neutron dose every epithermal neutron flux, 12×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1) gamma dose each epithermal neutron flux, 0 ratio of the thermal neutron flux to the epithermal neutron flux, 0.73 ratio of epithermal neutrons current to the total epithermal neutron flux. Fast neutron doses each epithermal neutron flux and gamma dose every epithermal neutron flux parameters has not met the IAEA’s criteria of less than 1×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1). However, for gamma dose every epithermal neutron flux parameter is still within the limits of tolerance of the IAEA which is less than 13×〖10〗^(-13) Gy 〖cm〗^2 s 〖neutron〗^(-1).
Kata kuncikolimator neutron, BNCT, MCNPX, reaksi 7Li(p,n)7Be, kriteria IAEA
Pembimbing 1Bilalodin, M.Si
Pembimbing 2R. Farzand Abdullatif, M.Si
Pembimbing 3
Tahun2015
Jumlah Halaman6
Tgl. Entri2015-08-19 07:01:23.92652
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.