Artikel Ilmiah : H1A011015 a.n. ARIFATIN ISTIQOMAH

Kembali Update Delete

NIMH1A011015
NamamhsARIFATIN ISTIQOMAH
Judul ArtikelVALIDASI METODE PENENTUAN MIKONAZOL DALAM SAMPEL OBAT SECARA KROMATOGRAFI CAIR KINERJA TINGGI
Abstrak (Bhs. Indonesia)Mikonazol merupakan salah satu obat antijamur yang termasuk dalam turunan imidazole. Senyawa ini biasanya digunakan secara topical (seperti kulit) atau pada membran mukosa untuk mengobati infeksi yang disebabkan fungi. Penelitian ini bertujuan untuk menetapkan validasi metode kromatografi cair kinerja tinggi (KCKT) pada penentuan mikonazol dan menentukan kadar mikonazol dalam sampel obat (powder) secara KCKT. Sampel dilarutkan dengan metanol lalu dianalisis secara KCKT menggunakan kolom C8 ukuran 150 x 4,6 mm, fase gerak metanol:air 85:15, laju alir 0,8 mL/menit dan deteksi pada panjang gelombang 220 nm. Validasi metode dilakukan berdasarkan parameter presisi, akurasi, linearitas, batas deteksi, batas kuantifikasi dan selektivitas. Validasi metode KCKT menunjukkan hasil uji presisi dengan KV = 0,96%, nilai %recovery sebesar 101,28 %, linearitas diperoleh koefisien determinasi sebesar 0,9983, nilai batas deteksi sebesar 2,24 ppm, nilai batas kuantifikasi sebesar 7,47 ppm dan uji selektivitas sebesar 2,21. Kadar mikonazol dalam sampel bedak (powder) diperoleh sebesar 1,965%.


Abtrak (Bhs. Inggris)Miconazole is an imidazole antifungal agent. It is commonly used to the skin or to mucus to cure fungal infections. The purpose of the research is to determine validation of high performance liquid chromatography (HPLC) method and determine the concentration of miconazole in drug sample (powder) by HPLC. Sample was eluted with methanol and then analyzed by HPLC using C8 column (150 x 4.6 mm), mobile phase of methanol:water 85:15, flow rate of 0.8 mL/minute and wavelength of 220 nm. The following validation characteristics were addressed by precision, accuracy, linearity, limit of detection (LOD), limit of quantification (LOQ) and selectivity. The result of HPLC method validation showed precision (RSD = 0.96%), recovery of 101.28 %, linearity with R2 value was 0.9983, LOD was 2.24 ppm, LOQ was 7.47 ppm and selectivity was 2.21. Concentration of miconazole in drug sample (powder) showed 1.965%.


Kata kunciKromatografi Cair Kinerja Tinggi, Mikonazol, Validasi Metode
Pembimbing 1Dadan Hermawan, Ph.D
Pembimbing 2Dr. Suwandri, S.Si., M.Si
Pembimbing 3
Tahun2015
Jumlah Halaman11
Tgl. Entri2015-07-29 13:41:03.481845