Judul ArtikelSTUDI PENGARUH KETIDAKSEIMBANGAN BEBAN ANTAR FASA PADA SISTEM DISTRIBUSI 20 KV DENGAN MENGGUNAKAN SOFTWARE ETAP 7.5.0 (STUDI KASUS GARDU INDUK KALIBAKAL FEEDER 01)
Abstrak (Bhs. Indonesia)Pada sistem distribusi, ketidakseimbangan beban sering terjadi karena pembagian beban trafo distribusi yang tidak merata yang mengakibatkan mengalirnya arus netral di penghantar netral. Penelitian ini dilakukan untuk menganalisis pengaruh ketidakseimbangan beban pada sistem distribusi penyulang Kalibakal 1. Parameter yang diteliti meliputi pengaruh ketidakseimbangan beban terhadap arus netral yang muncul beserta rugi daya akibat arus netral, jatuh tegangan dan rugi daya total pada penyulang. Metode pemerataan beban dilakukan dengan beberapa skenario untuk memperbaiki ketidakseimbangan beban. Pada kondisi awal pembebanan, nilai persentase ketidakseimbangan beban sebesar 38,67%. Dengan 3 skenario pemerataan beban yang dilakukan, nilai ketidakseimbangan beban berturut-turut mengalami penurunan menjadi 3,67%, 2,33% dan 0,63%. Nilai arus netral juga mengalami penurunan dari nilai awal sebesar 23,66A menjadi 2,09A, 1,41A, dan 0,60A. Dengan menurunnya arus netral, rugi total daya juga menurun dari nilai awal 1.652,77 W menjadi 1.153,29 W, 1.150,58 W, dan 1.150,08 W. Nilai persentase rugi daya dengan 3 skenario pemerataan beban menjadi 0,25% dari nilai awal 0,36%.
Abtrak (Bhs. Inggris)In the distribution system, unbalance-loads frequently occurs because of mal-distribution in the transformer loads which resulting neutral current flowing in the neutral conductor. This research is done to analyze the influence of unbalance-loads to the distribution system in feeder1 Kalibakal. Researched parameters included the effect of unbalance-loads on neutral currents that appear along with the power loss due to neutral currents, voltage drop and total power loss at feeder. Loads spreading method has been done with several scenarios to repair unbalance-loads. At the beginning conditions of loading, the percentage value of unbalance-loads is 38,67%. With 3 commited loads spreading scenarios, unbalance-loads value successively decreased to 3,67%, 2,33% and 0,63%. Neutral current value also decreased from 23,66A to 2,09A, 1,41A, and 0,60A. By decreasing of netral current, the total power loss is also decreased from 1.652,77 to 1.153,29 W, 1.150,58 W, and 1.150,08 W. A new percentage value of power losses is decreased to 0,25% from the beginning value of 0,36% with using 3 scenarios loads spreading.
Kata kunciSistem distribusi, ketidakseimbangan beban, losses, arus netral
Pembimbing 1Daru Tri Nugroho S.T., M.T.
Pembimbing 2Winasis S.T.,M.Eng.
Pembimbing 3
Tahun2015
Jumlah Halaman9
Tgl. Entri2015-05-14 23:11:10.111848
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.