Judul ArtikelAnalisis Distribusi Suhu dan Kelembaban Udara (RH) dalam Model Rak Tanaman Tertutup Menggunakan CFD (Computational Fluid Dynamics)
Abstrak (Bhs. Indonesia)Penelitian ini bertujuan untuk mengetahui distribusi suhu dan kecepatan aliran udara dalam Plant Factory menggunakan Computational Fluid Dynamics (CFD). Penelitian dilaksanakan di laboratorium Teknik Pengelolaan dan Pengendalian Bio Lingkungan, Universitas Jenderal Soedirman, Purwokerto. Variabel yang diamati adalah distribusi suhu, RH dan kecepatan aliran di dalam Plant Factory. Pembuatan mesh pada geometri dilakukan dengan perangkat lunak Geomesh dan perangkat lunak CFDSOF untuk simulasi CFD. Hasil penelitian menunjukkan bahwa simulasi menggunakan CFDSOF menunjukkan kesesuaian dengan pengamatan. Hal ini dinyatakan dengan nilai koefisien determinasi (R2) antara suhu hasil simulasi dengan suhu hasil pengukuran, nilai pada sensor 1 (rak 1) dan sensor 5 (rak 2) masing-masing sebesar 0,9 dan 0,8. Nilai R2 untuk kecepatan aliran hasil simulasi dengan hasil pengukuran sebesar 0,99 (tidak ada perbedaan). Distribusi suhu dan RH lebih seragam terjadi pada rak I, dengan suhu rata-rata rak I 250C, rak II 26,80C dan lingkungan 270C, sedangkan RH di dalam plant factory kisaran 58,27% hingga 73,69%.
Abtrak (Bhs. Inggris)This research aims to understand the distribution of temperature and flow velocity in plant factory using Computational Fluid Dynamics (CFD). This research was conducted in Laboratory of Bio-environmental management and control engineering, University of Jenderal Soedirman, Purwokerto. The variable observed is distribution of temperature, RH and flow velocity in plant factory. The meshing development in geometri were done using Geomesh software, while CFDSOF software used for CFD simulation. The results showed that simulation using CFDSOF in a good accordance with the observations. It is showed by determination coefficient (R2) between the temperature and measurement temperature. The R2 value on sensor 1 (shelf I) and sensor 5 (shelf II) are 0,9 and 0,8 respectively. R2 value for air flow velocity are the same for both simulation and measurement which is 0,99. Distribution of temperature and RH are more uniform in the shelf I, with average temperature of shelf I is 250C, while temperature of shelf II is 26,80C and environment temperature of 270C. RH in plant factory has value between 58,27% until 73,69%.
Kata kunciPlant Factory, Computational Fluid Dynamics (CFD)
Pembimbing 1Dr. Ardiansyah, S.TP., M.Si
Pembimbing 2Ropiudin, S.TP., M.Si
Pembimbing 3
Tahun2015
Jumlah Halaman9
Tgl. Entri2015-05-13 17:18:41.205051
Cetak Bukti Unggah
© Universitas Jenderal Soedirman 2026 All rights reserved.