| Judul Artikel | TEKANAN 100 mmHg WOUND VACUUM MODIFIKASI SELAMA 1 JAM PADA LUKA DIABETIKUM |
| Abstrak (Bhs. Indonesia) | Latar Belakang: Wound vacuum terbukti dapat mengatasi komplikasi penyakit DM. Wound vacuum modifikasi breast pump tekanan 100 mmHg selama 2 jam menyebabkan inflamasi memanjang. Oleh karena itu, diperlukan pengujian durasi penggunaan tekanan untuk mengetahui pengaruh terhadap penyembuhan luka DM. Tujuan: Penelitian ini akan menguji pengaruh tekanan wound vacuum modifikasi breast pump 100 mmHg selama 1 jam/hari terhadap penyembuhan luka tikus diabetikum. Metode: Penelitian eksperimen murni dengan pendekatan post test only with control group design. Pengelompokan subjek desain penelitian ini dibagi menjadi dua kelompok yaitu kelompok perlakuan dan kelompok kontrol. Kelompok perlakuan akan diberikan wound vacuum modifikasi breast pump bertekanan 100 mmHg dengan lama vakum 1 jam/hari, sedangkan kelompok kontrol menggunakan perawatan luka konvensional. Perawatan luka pada kedua kelompok dilakukan selama 7 hari dan pengamatan luka dilakukan secara makroskopis dan mikroskopis. Hasil: Pengamatan secara makroskopis pada kedua kelompok mengalami edema dari hari ke-2 sampai dengan hari ke-6. Slough pada kedua kelompok sama banyak. Warna luka pada kedua kelompok kemerahan dari hari ke-1 sampai dengan hari ke-2. Area luka pada kelompok perlakuan dan kontrol tampak sama pada hari ke-7. Hasil pengamatan secara mikroskopis didapatkan adanya inflamasi yang lebih banyak pada kelompok perlakuan dibandingkan pada kelompok kontrol dan reepitelisasi belum terbentuk pada kedua kelompok. Kesimpulan: Tekanan wound vacuum modifikasi breast pump 100 mmHg selama 1 jam/ hari tidak berpengaruh terhadap luka tikus diabetikum |
| Abtrak (Bhs. Inggris) | Background : The Backround of the research is Wound vacuum proven to overcome the complications of DM disease. Wound vacum modified breast pump pressured of 100 mmHg for 2 hours causes inflammatory compounds. Therefore, the required duration of the pressure test to determine the effect on wound healing DM. The Purpose : This research aimed to examine the effect Wound vacum modified breast pump pressured of 100 mmHg for 1 hour/day on wound healing diabetic rats. Methods: The research used pure experiment by approach posttest only with control group design. Grouping subjects research design is divided into two groups: They are the treatment group and the control group. The treatment group will be given Wound vacum modified breast pump which presured by 100 mmHg takes vacum time in 1 hour/day, while the control group using conventional wound care. The treatment of wounds in both groups performed for 7 days and the wound observation is done in both of macroscopic observations and microscopic observations. Results: The macroscopic observation in both groups edema on day 2 until day 6. Slough in both groups are equal in quantity. Wound area in both groups on day 7 are equal in quantity. The color of the wound in both groups redness on day 1 untill day 2. The results of this microscopic observation obtained inflammation more in the intervention group than in the control group and no reephitelization formed in both groups. Conclusion: The pressure Wound vacum modified breast pump in 100 mmHg for 1 hour /day had no effect on wounds of diabetic rats. |
| Kata kunci | Wound vacuum, wound vacuum modifikasi breast pump, luka diabetik |
| Pembimbing 1 | Ns. Yunita Sari, MHS.,Ph.D |
| Pembimbing 2 | Ns. Iwan Purnawan, S.Kep., M.Kep |
| Pembimbing 3 | Desiyani Nani, S.Kep., Ns., M.Sc |
| Tahun | 2015 |
| Jumlah Halaman | 10 |
| Tgl. Entri | 2015-02-23 22:35:02.718858 |