Artikel Ilmiah : H1D008037 a.n. MUHAMMAD ABDURAHMAN
| NIM | H1D008037 |
|---|---|
| Namamhs | MUHAMMAD ABDURAHMAN |
| Judul Artikel | AUDIT SISTEM PROTEKSI KEBAKARAN PADA GEDUNG PROF. DR. SOELARTO RUMAH SAKIT UMUM PUSAT FATMAWATI |
| Abstrak (Bhs. Indonesia) | Kebakaran bangunan merupakan suatu bencana yang merugikan bagi banyak pihak yang dapat mengakibatkan kerugian materil dan berpotensi terhadap kematian yang cukup besar sehingga memerlukan perhatian akan keselamatan penghuni bangunan. Oleh karena itu perlu disain bangunan yang memenuhi kriteria keamanan terhadap bahaya kebakaran. Bangunan yang digunakan sebagai objek penelitian adalah gedung Prof. Dr. Soelarto Rumah Sakit Umum Pusat Fatmawati. Penelitian ini bertujuan untuk mengetahui nilai keandalan sistem proteksi pasif, sistem proteksi aktif, sarana penyelamatan dan komponen kelengkapan tapak yang diterapkan oleh pengelola bangunan gedung Prof. Dr. Soelarto. Data primer didapatkan dari pengamatan langsung di lapangan sedangkan data sekunder adalah data yang diperoleh dari pengelola gedung itu sendiri, baik melalui wawancara maupun melalui gambar. Penilaian menggunakan alat bantu cheek list yang diambi dari Pd-T-11-2005-C, kemudian dinilai nilai keandalan sistem keselamatan bangunan tersebut. Hasil pengolahan data menunjukkan bahwa sistem proteksi pasif bernilai 21,16 %, sistem proteksi aktif bernilai 20,484 %, sarana penyelamatan bernila 21,13 % dan kelengkapan komponen tapak bernilai 19,909 %. Bangunan dinilai baik dan dapat menjamin keselamatan penghuni bangunan terhadap bahaya kebakaran karena nilai NKSKB (Komponen Keandalan Sistem Keselamatan Bangunan) sebesar 82,683 % (B) sesuai peraturan Pd-T-11-2005-C. |
| Abtrak (Bhs. Inggris) | Building fire is a disaster that affect many people like material losses and potentially enough leading to death. Therefore, the safety of the building occupants need to get attention. The building must has the standards required of the fire protection system. The building which used as the object of study is Prof. Dr. Soelarto building, Fatmawati Centrall Hospital. This study aims to determine the value of passive protection system against fire hazards, active protection system, safety facalities, and the completeness of the outdoor fire system infrastructure with case studies Prof. Dr. Soelarto building, Fatmawati Central Hospital. Primary data was obtained from direct observation in the field, while the secondary data was obtained from the data collected at building. Assessment and evaluation of the components fire protection system in buildings which refers to the standard assessment of Pd-T-11-2005-C. The study shows that passive protection system has a value 21.16%, active protection system 20.484%, safety facalities system 21.13% and the completeness of the outdoor fire system infrastucture 19.91%. The buildings included category B (good), that can guarantee the safety of the occupants of the building against fire with NKSKB (Nilai Keandalan Sistem Keselamatan Bangunan) value 82.683% (B) in accordance as the rules pd-T-11-2005-C. |
| Kata kunci | Audit, sistem proteksi kebakaran, Fatmawati |
| Pembimbing 1 | Paulus Setyo Nugroho, ST., MT |
| Pembimbing 2 | Bagyo Mulyono, ST., MT |
| Pembimbing 3 | |
| Tahun | 2015 |
| Jumlah Halaman | 20 |
| Tgl. Entri | 2015-02-19 15:14:32.525371 |