Home
Login.
Artikelilmiahs
8812
Update
DESSY ARUM NOVITASARI
NIM
Judul Artikel
RANCANG BANGUN INKUBATOR PORTABLE DENGAN SISTEM OTOMATISASI PEMANTAU SUHU MENGGUNAKAN SENSOR NEGATIVE TEMPERATURE COEFFICIENT (NTC)
Abstrak (Bhs. Indonesia)
Sebuah inkubator portable dengan sistem otomatisasi pemantau suhu menggunakan sensor Negative Temperature Coefficient (NTC) telah berhasil dibuat sebagai alat bantu menstabilkan suhu BBLR. Tahap awal perancangan ini melakukan karakterisasi sensor NTC dengan hasil hubungan suhu terhadap resistansi. Inkubator portable dirancang dengan mendesain ulang selimut bayi dengan penambahan modul XH-W1207 dan elemen pemanas peltier. Pengukuran suhu dilakukan untuk mengetahui kestabilan dan sebaran suhu di permukaan bagian dalam selimut dengan dan tanpa objek. Kinerja inkubator diuji dengan memantau perubahan suhu dari waktu 0 sampai 5 jam. Waktu respon sensor sekitar 2 menit. Dari pengujian dengan ada dan tanpa objek dalam inkubator diperoleh awalnya pergerakan suhu ruangan rata-rata naik dari waktu 0 sampai 1 jam. Namun dari waktu 1 sampai 5 jam pergerakan suhu rata-rata cenderung stabil. Suhu ruangan rata-rata terukur di dalam inkubator portable dengan dan tanpa objek berkisaran antara 34,0-35,7 derajat Celcius. Berdasarkan pemetaan sebaran suhu ruangan pada inkubator dengan dan tanpa objek, belum memperlihatkan sebaran suhu ruangan yang merata atau tidak terdistribusi dengan baik. Untuk mendapatkan hasil yang sesuai dan maksimal, maka desain inkubator hendaknya disempurnakan kembali.
Abtrak (Bhs. Inggris)
A portable incubator with temperature monitoring automation system using Negative Temperature Coefficient (NTC) censor was successfully designed as an instrument to stabilize Low Birth Weight (LBW) babies temperature. The first step of this design is conducting NTC censor characterization the result of temperature relation towards resistance. Portable incubator was designed by redesigning the baby blanket with module increase of XH-W1207 and element of peltier. The measure of the temperature was performed to determine the stability and distribution of the room temperature with the existing circumstances and without object. The work of this incubator was examined by monitoring room’s temperature changes from 0 to 5 hours. The time response of censor is approximately about 2 minutes. From the examination with and without involving an object into incubator was obtained the average of room’s temperature movement from 0 to 1 hours. However, from 1 to 5 hours of the temperature movement was tend to stable. The average of room’s temperature was measured in the incubator portable without and with an object is about 34,0 -35,7 derajat Celcius. Based on temperature’s mapping within incubator with or without involving an object has not showed the spread of room’s temperature evenly or has not distributed. To get the appropriate and maximum, the design of the incubator should be refined again.
Kata kunci
Pembimbing 1
Pembimbing 2
Pembimbing 3
Tahun
Jumlah Halaman
Save