Home
Login.
Artikelilmiahs
42747
Update
DANI SUTOPO PUTRA
NIM
Judul Artikel
Perbandingan Distribusi Dosis Serap Radiasi Co-60 dan LINAC pada Kanker Servik dengan Dua Sudut Arah Penyinaran Menggunakan Metode Monte Carlo
Abstrak (Bhs. Indonesia)
Penyinaran radioterapi pada kanker serviks memerlukan perencanaan. Treatment Planning System (TPS) radioterapi diperlukan untuk memaksimalkan dosis serap sel kanker dan meminimalkan dosis serap pada organ sekitar. Salah satu cara mengetahui distribusi dosis serap pada kanker serviks maka diperlukan simulasi menggunakan Monte Carlo . Monte Carlo menggunakan metode probabilistik karena perjalanan foton secara acak dan heterogenitas organ yang diradiasi. Pemodelam phantom organ dilakukan mengacu pada ukuran tubuh wanita dewasa di Asia menggunakan Taiwanese Reference Woman. Penelitian ini bertujuan untuk menentukan perbandingan distribusi dosis serap radiasi antara Co-60 dan LINAC pada sel kanker serviks dan organ sekitar, dengan teknik penyinaran sudut 0˚dan 180˚, serta ‘’’’menentukan perbandingan distribusi dosis serap gabungan dari variasi penyinaran dalam bentuk kontur radiasi berdasarkan target volume (GTV, CTV dan PTV) ICRU 50. Berdasarkan hasil penelitian perbandingan dosis serap gabungan yang dihitung dari dua sudut penyinaran 0º dan 180 º, dosis radiasi paling maksimal terjadi pada radioterapi LINAC yaitu pada target radiasi GTV sel kanker 1,91 Gy, kandung kemih 1,71 Gy, serviks 1.90 Gy, dan rektum 1,21 Gy. Hasil target radiasi GTV sel kanker berada dibawah rentang dosis radiasi yang diperbolehkan yaitu 1,5-2,5 Gy. Distribusi dosis serap maksimum terdapat pada target radiasi tepat mengenai sel kanker dan memenuhi syarat laporan ICRU 50. Dari penelitian yang telah dilakukan, dapat dibuktikan bahwa hasil dosis radiasi yang diserap sel kanker dari pesawat radioterapi LINAC lebih baik daripada hasil dosis radiasi dari pesawat Co-60.
Abtrak (Bhs. Inggris)
Radiotherapy for cervical cancer requires planning. Radiotherapy Treatment Planning System (TPS) is needed to maximize the absorbed dose to cancer cells and minimize the absorbed dose to surrounding organs. To determine the distribution of absorbed dose in cervical cancer, a Monte Carlo simulation is needed. Monte Carlo uses probabilistic methods due to the random travel of photons and the heterogeneity of irradiated organs. Phantom organ modeling was carried out referring to the body size of adult women in Asia using the Taiwanese Reference Woman. This study aims to determine the comparison of the radiation absorbed dose distribution between Co-60 and LINAC on cervical cancer cells and surrounding organs, using 0˚ and 180˚ angle radiation techniques, as well as determine the comparison of the combined absorbed dose distribution of the radiation variations in the form of Treatment Planning radiation contours. System (TPS) based on target volume (GTV, CTV and PTV) ICRU 50. Based on the results of research comparing the combined absorbed dose calculated from two radiation angles of 0º and 180º, the maximum radiation dose occurs in LINAC radiotherapy, namely at the GTV radiation target of cancer cells 1.91 Gy, bladder 1.71 Gy, cervix 1.90 Gy, and rectum 1.21 Gy. The results of the GTV radiation target for cancer cells are below the permitted radiation dose range, namely 1.5-2.5 Gy. The distribution of the maximum absorbed dose is found in the radiation target that directly hits the cancer cells and meets the requirements of the ICRU 50 report. From the research that has been carried out, it can be proven that the results of the radiation dose absorbed by cancer cells from the LINAC radiotherapy aircraft are better than the results of the radiation dose from the Co-60 aircraft.
Kata kunci
Pembimbing 1
Pembimbing 2
Pembimbing 3
Tahun
Jumlah Halaman
Save