Analisis Kinerja dan Koordinasi Directional Over Current Relay Pada Penghantar 30 kV Kalibakal - Ketenger GI Kalibakal
Abstrak (Bhs. Indonesia)
Sistem proteksi pada penghantar merupakan sistem pengamanan listrik yang membatasi jika terjadi gangguan di zona proteksi suatu penghantar agar mengurangi kerusakan di daerah yang terganggu. Bagian komponen yang paling sering terkena gangguan ada pada kawat transmisi (70% s.d. 80% dari seluruh gangguan). Dalam sistem proteksi penghantar, gangguan dapat diproteksi dengan beberapa relai, salah satunya DOCR (Directional Overcurrent Relay) untuk proteksi cadangan. Relai DOCR bekerja secara selektif mengamankan saluran transmisi dari gangguan eksternal dan internal. Salah kerja pada relai dapat menyebabkan kurang handalnya suatu sistem proteksi saat terjadi gangguan. Relai DOCR pada penghantar 2 bekerja mendahului penghantar 1 saat terjadi gangguan petir di zona penghantar tertentu. Waktu kerja relai untuk DOCR pada sisi Ketenger penghantar 2 di perbesar dari 0.4 s menjadi 1 s. Dengan demikian nilai pada Tms juga berubah dari 0.1 menjadi 0.25. Resetting dilakukan agar sistem kerja relai dapat berjalan lebih baik. Selanjutnya dilakukan simulasi koordinasi relai pada software ETAP 12.6.0. Hasil simulasi data aktual dilapangan dan hasil simulasi perhitungan matematis akan dibandingkan untuk mengetahui keandalan relai. Secara khusus penelitian ini membahas analisis gangguan hubung singkat pada penghantar yang diproteksi menggunakan relai DOCR berdasarkan standar IEEE.
Abtrak (Bhs. Inggris)
The protection system on the conductor is an electrical security system that limits if there is a disturbance in the protection zone of a conductor in order to reduce damage in the disturbed area. The component parts that are most often affected by interference are in the transmission wire (70% to 80% of all disturbances). In the conductor protection system, disturbances can be protected by several relays, one of which is DOCR (Directional Overcurrent Relay) for backup protection. The DOCR relay works by selectively securing the transmission line from external and internal interference. Wrong work on the relay can cause a less reliable protection system in the event of a disturbance. The DOCR relay on conductor 2 works ahead of conductor 1 when there is a lightning disturbance in a certain conductor zone. The working time of the relay for DOCR on the Ketenger side of conductor 2 was increased from 0.4 s to 1 s. Thus the value of Tms also changes from 0.1 to 0.25. Reset is done so that the relay system works better. Furthermore, the relay coordination simulation was carried out on the ETAP 12.6.0 software. The simulation results of the actual data in the field and the simulation results of mathematical calculations will be compared to determine the reliability of the relay. In particular, this study discusses the analysis of short circuit faults in conductors that are protected using a DOCR relay based on the IEEE standard.
Kata kunci
Pembimbing 1
Pembimbing 2
Pembimbing 3
Tahun
Jumlah Halaman
Save